25
Part 2 - USE AND MAINTENANCE INSTRUCTIONS
2 - Replacing
Remove the grease filters and take out the activated charcoal filter from its housing,
turning the lugs provided
(fig. 30)
. Insert the new activated charcoal filter and replace
the metal grease filters.
3 - Enabling the alarm signal
In recirculation type hoods the saturated filters alarm must be enabled as indicated
below:
- Turn off the lights and the suction motor;
- Press and hold the
Speed
+ button for at least 10 seconds, until the LEDs start to
flash. Note the number of flashes:
- 2 flashes of the LED Activated charcoal filter saturation alarm
ENABLED
.
- 1 flash of the LED Activated charcoal filter saturation alarm
DISABLED
;
4 - Resetting the alarm signal
To turn the alarm signal off, proceed as follows:
- Press the
Speed
+ button for at least 3 seconds, until the LEDs flash in confirmation.
In any case the saturated filters alarm will only come into operation when the suction
motor is turned on.
WARNING: always comply with the maintenance and replacement times
indicated, in order to avoid a possible risk of fire when the filters are saturated
with grease.
3.3 - Light
1 - It consists of 2 20 W-halogen spotlights.
2 - Replacement (
fig. 31
)
Remove the two screws that lock the metal ring,
take the spotlight out of its holder by pulling
slightly. When replacing, make sure that both pins
are well inserted in the holder seat.
3.4 - Cleaning
Normal cleaning operation of the hood:
- Do not use any wet cloth or sponge or water-jet.
- Do not use diluents or alcohol, as they could make the painted surfaces opaque.
- Do not use abrasive products, especially on stainless steel surfaces.
We recommend the use of a damp cloth and any neutral liquid detergent.