background image

Cleaning, care and maintenance

Caution!

 For repair work or cleaning the inside of the hood,

switch off the household fuse.

Caution! 

Do not use any scouring agents or aggressive cleaners.

Control panel

Carefully wipe the control panel now and again with a soft cloth which is
free of fluff.

Glass surfaces

Clean the fume trap and the glass shelf with a damp cloth and a little
hand detergent or one of the usual glass cleaning agents

Stainless steel parts

Clean stainless steel parts with a damp cloth and a little hand detergent.
Then wipe dry. Use one of the usual stainless steel cleaning agents from
time to time.

The hood may be cleaned when necessary on the inside with a damp
cloth and hand detergent.

Cleaning the metal fat filters

Both metal fat filters must be cleaned if all the control lights on the control
panel flash at the same time.

Grip the filter cover at the open-
ing, push outwards, turn
downwards and unhook out of the
opening in the lamp holder.

For recirculation mode: Remove the holders of the activated charcoal fil-
ters as well as the filters themselves (see Section “Changing the activa-
ted charcoal filters”).

Clean the meshes with the fat filters in the dishwasher or by hand with a
mild detergent. Before installation, rinse well and dry.

For recirculation mode: Insert the activated charcoal filters again and
secure with the holders.

Insert both filters again: To this
end insert the two brackets of one
cover into the openings provided
in the lamp holder, press the filter
upwards and then push inwards
until it is firmly in position.

If the control lights still flash when the hood is used for the first time af-
ter cleaning, press one of the lower three buttons. The counter for the
operating hours is then reset to 0 and the control lights go off.

Changing the activated charcoal filters (for
recirculation mode)

The activated charcoal filters absorb odours until they are saturated. They
cannot be cleaned or regenerated and have to be replaced with new origi-
nal replacement filters after 6 months at the latest.

Remove the meshes with the met-
al fat filters on both sides and cle-
an (see “Cleaning the metal fat fil-
ters”).

Remove the holders and take out
the used activated charcoal filters.

Insert new activated charcoal fil-
ters and secure with the holders.

Install the filter covers again.

Replacing a halogen lamp

Caution!

 The halogen lamps become very hot after being in use

for some time. Therefore, the lamps should be changed when
they have cooled down.

Only replace the halogen lamps with 

lamps of the same type.

Do not grip the halogen lamps with your bare hands. Finger marks 
burn into the lamp glass and reduce the light intensity and service 
life of the lamps. 

Carefully lever out the halogen
lamp with a screwdriver and pull
downwards out of the holder.

Carefully push a new lamp (20
Watt) into the socket using a cloth.

KD 965.1 / KDEM 965.1

15

Summary of Contents for KD 965.1

Page 1: ... for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem KD 965 1 KDEM 965 1 537 517 G61 ...

Page 2: ...s and functions For operating your cooker hood For operating the hood with stoves and heating appliances with a naked flame General advice 13 Your appliance at a glance 14 Using the hood 14 Before using your appliance for the first time Switching the lighting On Off Switching on the ventilation Changing the ventilation setting Switching the ventilation off Switching on the delayed stop time Cleani...

Page 3: ... used simultaneously in rooms where a negative pressure of 0 04 mbar is not exceeded This ensures that the fumes from the stove are not sucked back into the room This can be achieved if there are non airtight openings in windows and doors ventilation wall boxes supplying extracting air or other technical devices e g interlock devices so that a sufficient supply of combustion air can flow back into...

Page 4: ...he hood in the settings 2 to 4 after 10 minutes After switching the hood on press the respective setting button a se cond time With the timer activa ted the control light of the setting selected flashes Press the button 0 1 to switch off the hood before the time lapses Cleaning interval for the fat filters After about 30 hours of operation all the control lights flash at the same time to remind yo...

Page 5: ...re with the holders Insert both filters again To this end insert the two brackets of one cover into the openings provided in the lamp holder press the filter upwards and then push inwards until it is firmly in position If the control lights still flash when the hood is used for the first time af ter cleaning press one of the lower three buttons The counter for the operating hours is then reset to ...

Page 6: ... defective Pull out plug or switch off fuse Call Customer Service Halogen lighting does not work Lamp defective Replace lamp LED does not work LED defective Call Customer Service Performance of the cooker hood is re duced Filters very clogged Replace filters Several LEDs flash Not a defect see Cleaning the metal fat filters Rating label The rating label can be seen when you have removed the fat fi...

Page 7: ...enclosed dowels and screws are suitable for walls made of perfora ted bricks or concrete bricks which are 20 mm thick For solid concrete walls you must use special concrete dowels from a specialist store For solid wooden walls you must use wood screws of sufficient thick ness and length Electric connection The hood is fitted with a normal mains plug and there should therefore be a socket outlet 23...

Page 8: ...y The chimney consists of two parts The upper part has ventilation slits the lower part recesses for the control buttons The recesses for the control but tons must always be at the bot tom The chimney parts can be pulled apart and pushed together again as required Recirculation mode The ventilati on slits must be at the top Extraction mode The ventilation slits must be at the bottom so that they a...

Page 9: ...he control buttons protrude slightly forwards out of the chimney Inserting the metal fat filters Before you install the filters again you should read off the serial number and the model designation on the rating label and enter them on page 16 Only appliances with recirculation mode Place an activated charcoal filter in each filter cover and secure with the holders All appliances Mount both filter...

Page 10: ...pe must not exceed 2 5 m The pipe must be heat insulated or an air trap seal must be installed Extraction into an existing exhaust shaft The exhaust air must only be introduced into an existing exhaust shaft if this is insulated against damp and is not already used for fuel purposes Have the chimney sweep responsible approve the use of the shaft Please note If the extraction channel is led through...

Reviews: