background image

KD9890.0

BEDIENUNGSANWEISUNG

mit  Montageanweisungen

GB

Instructions for use and installation instructions
Instructions d'utilisation et avis de montage
Gebruiksaanwijzing en montagehandleiding
Istruzioni di uso e di montaggio
Instrucciones de uso y de montaje
Instruções de uso e de montagem

ÏÄÇÃÉÅÓ ÃÉÁ ÔÇÍ ÅÃÊÁÔÁÓÔÁÓÇ ÊÁÉ ÔÇ ×ÑÇÓÇ

F

NL

I

E

P

GR

Summary of Contents for KD9880.0

Page 1: ...use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem ÏÄÇÃÉÅÓ ÃÉÁ ÔÇÍ ÅÃÊÁÔÁÓÔÁÓÇ ÊÁÉ ÔÇ ÑÇÓÇ F NL I E P GR ...

Page 2: ...nted read the following this appliance has such technical particulars that it belongs to class II insulation therefore it must not be earthed The following warning is valid in the United Kingdom only in case your cable is not furnished with a plug read the following instructions as the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifyin...

Page 3: ...tances indicated in Fig 4 Drill the 2 holes and fit the screw anchors provided As already specified on the Warnings sheet bear in mind that the distance between the lower edge of the hood and the hob must be min 650 mm Fix the metal bracket A to the wall using the 2 holes just drilled Fig 5 the screws for fixing the bracket are provided Use the 2 cut out triangles on the bracket to position it exa...

Page 4: ...n See point 10 of the instructions 1 Key A ASC function To activate the sensor function press key A With the sensor activated the hood switches on automatically in the presence of any type of odour steam smoke or heat from the cooking process and also in the presence of any anomalous gas leaks in the environment When the sensor is active the display shows the symbol To disactivate the sensor press...

Page 5: ...ters specialattentionmustbegiventothegreasefilterswhichmustbeperiodicallycleaned whenever the grease filter alarm trips For instructions of the filter Alarm refer to the Controls paragraph Remove the filters as shown in para 1 and wash with neutral detergent Replacing the charcoal filters ifthefilteringversionapplianceisused thecharcoalfilterswillhavetobeperiodically replacedwhenthecharcoalfiltera...

Page 6: ...e déchargé dans une cavité du mur à moins que cette cavité soit prévue pour ce but Prévoyez une aération de la pièce adéquate quand une hotte et des appareils alimentés par une énergie autre que l énergie électrique poêle à gaz à huile à charbon etc sont utilisés en même temps En effet en évacuant l air la hotte pourrait créer une dépression dans la pièce La pression négative de la pièce ne doit p...

Page 7: ...1 2 3 4 5 ...

Page 8: ...6 7 8 9 10 11 ...

Page 9: ...12 13 14 15 16 17 18 ...

Reviews: