background image

© Kurth Electronic GmbH, All Rights Reserved

5

Controller KE910

KE910 has eight control buttons, two connec

-

ting cables with banana plugs and a built-in

loudspeaker. This allows KE910 to be used as 

a PROBE for contactless location of cables or 

wire pairs. After the wire pair to which the KE905 

Remote has been connected has been found, 

the KE910 is connected firmly with clamps

 

or isolating plugs. 

This is necessary for remote control of the remote unit.

Attention: Before connecting the controller KE910 for remote control, 

the connection to the terminal device must be disconnected.
INFO LED

When a control command is sent, the INFO LED lights up for 1 second to 

confirmthis.IfthecontrolcommandisdetectedandexecutedbytheRemote

KE905, a high acknowledgement tone is heard. If the command is not reco

-

gnized or not executed, the LED does not light up and an interrupted error 

tone is heard.

LS search tone

TheLSkeyactivatesthesearchtonespeakerandboththesearchtonesent

byKE905Remoteandtheportcanbeswitched.Tofindtheunknownline,

oneofthetwotestcordsisusedasanantennainordertobeabletofind

the line you are looking for without touching it. The PROBE KE410 (Art. No. 

0.49561-4)canalsobeusedforthispurpose.Tocontroltheremotefunc-

tions, the line must be connected metallically.

Functions

Shift key

TheShiftkeyisusedtoperformcontrolfunctionsonthesecondlevel.Hold

downtheShiftkeyandpressthedesiredsecondkeytocontrolthefunction.

}

Tone

no

tone

Low 

Batt

INFO

1

2

3

4

5

Connected

Connected

KE910

 

CONTROLLER

Trace ON

Shift

LS

Open

Port 1 + Port 4

Schleife 

Port 1

Loop pulse 3 sec

Port 1

Port 1 + Port 2 

Port 1 + Port 3

Second level

OFF

  

- Stop Trace

Change Trace Tone

Port 1

Port 4

Tone 1 / 2

Port 2

Port 3

Mode

On-Off

GND

Port 1

Port 4

Port 2

Port 3

GND

Mode

On-Off

In the 

default mode

 

a  configurable  tone  is

 

output on port 1.

Shift + LS key

Port 1 is connected to 

port 4.

Summary of Contents for KE901

Page 1: ...ncluding excerpts require prior written approval of Kurth Electronic GmbH All of the brand names and trademarks cited herein are the property of their registered owners Operating Manual Kurth Electron...

Page 2: ...10 indispensable for Work without a second or third person as a measuring assistant For use in areas such as underground distributors cable ducts etc without communication access Ensuring the customer...

Page 3: ...an 1 second Then the green LED will show the selected mode As default trace tone 1 is on Port 1 To change the mode press the Mode button longer than 1 second and release Every press changes the mode F...

Page 4: ...port 1 If the exchange is to be switched through when the line end is known so that the line is not left without service for the time of the start and departure this can be selected by repeatedly pre...

Page 5: ...errupted error tone is heard LS search tone The LS key activates the search tone speaker and both the search tone sent by KE905 Remote and the port can be switched To find the unknown line one of the...

Page 6: ...tone and port sent by KE905 Remote Shift key OFF Port 1 is connected to port 2 and port 3 is in dependently connec ted to port 4 This allows independent measurements on two separate wire pairs Port 1...

Page 7: ...anana plugs Modified DTMF control signals Gain Probe function min 56 dB Overvoltage protection up to 160 V AC DC 1x 9 V battery min battery life 40 hours at 450 mAh battery and use of speaker 10 Dimen...

Page 8: ...ications for which it was not intended can lead to incorrect measure ments and may damage the device The relevant safety regulations in VDE 0100 0800 and 0805 must be adhered to The usage of connectio...