24
3BA00217 • 2020-10-26 • Rev. 3
Ersa EASY ARM 2
Functional Description
6.
Functional Description
Unfold the front cover before reading further. The mentioned pictures
can be found on these pages.
All device settings are made via the two push buttons on the display.
Display
①
is on the left side and display
②
is on the right one. Except
when in master-slave mode, both sides can be set independently of one
another. The upper push button is referred to as button
❶
and the lower
push button as button
❷
. The buttons are active as long as they are lit
and inactive when they are not lit.
The following table describes the possible settings and how they are
made:
Fig.
Description
To set the extraction capacity:
After switching on, operation continues with the last set extraction capacity.
By pressing and holding down button
❶
, the extraction capacity is continuously increased.
By pressing and holding down button
❷
, the extraction capacity is continuously decreased.
The extraction capacity can be increased/decreased. Both buttons are active.
Maximum extraction capacity is reached. Beep & button
❶
inactive. Button
❷
is active.
Minimum extraction capacity reached. Beep & button
❷
inactive. Button
❶
is active.
To reset the filter operating time:
Press and hold down button
❶
and button
❷
.
Switch on the device. Wait 10 seconds/10 beeps.
Release both buttons at the same time.
To reset to factory settings:
Press and hold down button
❶
and button
❷
.
Switch on the device. Wait 3 seconds/3 beeps.
Release both buttons at the same time.
To connect to a soldering station or a rework system:
The solder fume extraction EASY ARM 2 can be connected to the following Ersa soldering equipment:
i-CON 1 C and i-CON 2 C, i-CON VARIO 2 and i-CON VARIO 4, or an Ersa rework system.
Connect the interface cable (3CA10-2003) to the interface connector A or B of the soldering station or
of the rework system, and to the remote port 1 or 2 of the extraction device.
To set the master-slave mode:
The extraction device is selectively
and completely controlled via display
①
or display
②.
Here, display
①
acts as the master one: Press button
❶
on display
①
and button
❷
on display
②.
Should display
②
act as the master one, press button
❷
on display
①
and button
❶ on
display
②.
You will hear 5 short single beeps and one double beep. The master-slave mode is enabled; settings
can only be made on the display of the master page.
To disable the master-slave mode:
K
Press and hold button
❶
on display
①
and button
❶
on display
②
at the same time. You will hear
5 short single beeps and one double beep. The master-slave mode is disabled and the device accepts
the settings previously used. Settings can be made on both displays again.
ersa
EASY ARM 2
Summary of Contents for 0CA10-002
Page 90: ...90 3BA00217 2020 10 26 Rev 3 Ersa EASY ARM 2 3 3 1...
Page 91: ...91 3BA00217 2020 10 26 Rev 3 Ersa EASY ARM 2 8 3 2...
Page 93: ...93 3BA00217 2020 10 26 Rev 3 Ersa EASY ARM 2 5 5 1 EASY ARM 2 5 2 8...
Page 96: ...96 3BA00217 2020 10 26 Rev 3 Ersa EASY ARM 2 8 1 8 2 6 8 3...