26
3BA00217 • 2020-10-26 • Rev. 3
Ersa EASY ARM 2
Maintenance
8.1
Inserting/Replacing the Pre-Filter
The pre-filter must be inspected every three months and replaced if
necessary.
■
Make sure the device is switched off.
■
Open the cover of the extraction device by pressing the lugs on the hous
-
ing sides inwards.
■
Remove the used pre-filter.
■
Insert the new pre-filter with the white side facing up.
■
Re-attach the cover of the extraction device. Make sure that the lugs on
the housing sides are both engaged again.
The device is ready for use again.
8.2
Inserting/Replacing the Combination Filter
■
Make sure the device is switched off.
■
Open the cover of the extraction device by pressing the lugs on the hous
-
ing sides inwards.
■
Remove the used pre-filter and the combination filter of that side, which
is indicated by display
①
or display
②.
■
Note down the replacement/insertion date on the label of the new com
-
bination filter.
■
Insert the new combination filter centrally into the housing.
■
Insert the new pre-filter with the white side facing up.
■
Re-attach the cover of the extraction device. Make sure that the lugs on
the housing sides are both engaged again.
■
Reset the filter operating hours (see Chapter 6 and Figure
).
The device is ready for use again.
8.3
Cleaning the inside of hoses and arms
■
Clean dry with a dishwashing brush.
■
Then blow out with compressed air.