3BA00174 • 2014-02-06 • Rev. 5
HR 100 1 / 29
6.
Description of function
6.1.4.6 Heating power rise speed
Parameter [Ramp]
The following prerequisites must be met to be able to use this function:
• Either the thermocouple or the IR sensor must be connected to the base station.
• The connected sensor must be set in parameter [Alternative sensor]
.
• Thermocouple or IR sensor must be placed near the component to be processed.
• In the parameter [End temperature]
a value for the permissible end temperature
must be set.
■
You can now use this level to set the heat output rise speed (ramp) on the Hybrid Tool.
Press the rotary encoder to open the parameter [Ramp]
:
■
The setting range is
to
. Turn the rotary encoder clockwise or anti-clockwise,
until the desired value is displayed, e.g.
. Then press the rotary encoder to save the
adjusted value and to exit the parameter [Ramp]. The display shows
again.
You can set the rate of rise in defined steps of 0.5°K per second. The
control will then automatically compute the required energy level. Please pay
attention to the example on the next page.