3BA00174 • 2014-02-06 • Rev. 5
HR 100 1 / 39
6.
Description of function
■
Press the Start / Stop button on the Hybrid Tool. The set time is started and the Tool is
heated up. The display will first show the reading
, followed by the elapsed heating
time, e.g.
. During the last ten seconds of the heating time a reminding signal will
sound every second. Once the complete time has elapsed, the heating time is finished and
the cooling phase starts. The display shows the reading
.
■
Once the solder has melted, press the Start / Stop button to stop the heating process and
to start the cooling phase.
■
Desoldering:
Press the Start / Stop button to start the heating process.
■
Once the solder has melted, remove the component with a suitable tool or a vacuum pi-
pette. Press the Start / Stop button to stop the heating process and to start the cooling
phase.
■
If a vacuum pipette is used which is attached permanently to the stand: after the solder
has been molten, position the component under the pipette and lift the component with
the pipette.
We recommend the use of a solder smoke extraction device.
6.5
Connecting a PC
Via the USB-port the base station can be linked to a Windows PC and operated with the
software
IR-Soft
. Read the
IR-Soft
User Manual. The USB-port is located on the right side of
the base station housing at display level.