3BA00174 • 2014-02-06 • Rev. 5
HR 100 1 / 44
7.
Treatment of faults
7.4
Factory settings [Default]
The following table contains information about the settings of the base station upon delivery.
You can restore this delivery state:
■
Press and hold the rotary encoder before switching on
■
Switch on the station, hold the rotary encoder depressed for approx. two seconds. The
current firmware version appears in the display, e.g. [1.2.3]. Then release the rotary enco-
der. The factory settings have been restored.
Factory settings
Parameter
Prog. 0
Prog. 1
Prog. 2
Prog. 3
Unit
[Run time]
120
120
90
80
s
[Energy Level]
10
10
10
10
-
[Energy Level tool]
15
15*
15*
15*
-
[Blower speed]
10
1*
5*
15*
-
[Alternative sensor]
SE2
SE2*
SE2*
SE2*
-
[Ramp]
0
0*
0*
0*
°K/s
[End temperature]
240
240*
240*
240*
°C
Global settings (can only be changed with IRSoft)
Temperature unit
SDgr
°C
Buzzer settings
Low
*
These parameters are not changeable.