6 | Function description
The [Management] tabulator with three dialog windows
shown in the display and button bar on the top right. A number of the required
firmware updates will appear on the bell icon. Click on the bell icon and start
the update, which will be run automatically.
– [Satellites update file]: to refresh the heating head’s and lower heating’s firm-
ware, click on button [Open] and select the new satellite firmware with file ex-
tension *.bin. Then click on button [Firmware update]. The Satellite firmware
has been updated.
Normally, you will realize a firmware update is needed via a bell icon being
shown in the display and button bar on the top right. A number of the required
firmware updates will appear on the bell icon. Click on the bell icon and start
the update, which will be run automatically.
– [Amtel update file:]: only execute if specified by the Ersa service.
– [Xmos update file:]: only execute if specified by the Ersa service.
– Button [Firmware update]: to start updating the firmware. The version of the
installed firmware is displayed in dialog [Motion control information]. With re-
gard to this, please read Chapter The display and switch row top right.
[Optional tools]
– [Scavenger active]: Only with Scavenger residual solder sucker installed. Enable
work step [Scavenging] with Scavenger. With regard to this, please read
Chapter The [Process automation] buttons under the [Profile management]
tabulator. Read the relevant operating instructions before starting up the Scav-
enger residual solder sucker.
Ersa GmbH
Operating instructions HR 550 XL EN 3BA00247-01 | Rev. 1
100 / 157