6 | Function description
The [Management] tabulator with three dialog windows
c) Slide the PCB clamps outwards so that the pipette can directly come into con-
tact with the PCB holder.
d) Go on to the next work step.
ð
The nozzle comes into contact with the PCB holder and the height is learnt.
DANGER
Laser beam! Risk of injury due to retinal burns
a) Do not stare into the laser beam!
b) Do not point the laser beam at other people! Reflecting surfaces under the laser
generate reflections!
c) Class 2 laser according to DIN EN 60825-1:2008-5, P < 1 mW, λ = 650 nm
a) The position laser is on. Clamp the black plate in the PCB holder in such a way
that the laser beam is in the middle.
b) Use the laser with its printed side facing down to place the round focusing
small plate exactly in the middle of the black plate.
c) Go on to the next work step.
ð
The pipette picks up the focusing small plate.
Ersa GmbH
Operating instructions HR 550 XL EN 3BA00247-01 | Rev. 1
103 / 157