8 | Service and maintenance
Lubricating the worm gear of the pipette hub every six months
Fig. 37:
1 housing blower
a) Clean it if dirty. If in doubt replace it.
8.2 Lubricating the worm gear of the pipette hub every six months
Every 6 months lubricate the worm gear of the pipette hub. Switch off the Rework
System via the main switch before any cleaning and maintenance work!
Required material:
– 2 Allen keys
– Lubricating grease Klüber Micolube GL 261
Fig. 38:
1 inspection flap
a) Switch off the Rework System.
b) Remove one screw from the inspection opening with the Allen key and loosen
the other screw.
NOTE
For lubrication, a thin film of grease is enough!
If the drive components are excessively lubricated, they get dirty very quickly. Clean
dirty drive components before lubrication!
a) Use a grease brush to sparingly apply grease to the worm gear.
b) Screw the maintenance flap back on.
Ersa GmbH
Operating instructions HR 550 XL EN 3BA00247-01 | Rev. 1