2 | Technical data
Ambient conditions
2.2 Ambient conditions
Description
Ambient temperature (°C)
18…26, constant
Air humidity (%, non-condensing)
40…60
2.3 Connection data
Fig. 1:
Plug CEE 16 A, blue
Designation
Mains voltage 3-wire system N/PE (V)
1 x 230 V
Voltage tolerance (%)
± 10
Mains frequency (Hz)
50 - 60
Fuse (A)
16
Power consumption (kW)
3,68
Connection
CEE16 A
2.4 Printed circuit boards and components
Designation
PCB cooling from below
Blower
Max. PCB size (width x depth, mm)
530 x 610 (20.8“ x 24“)
Min. PCB size (width x depth, mm)
20 x 20
Max. PCB thickness (mm)
10
Min. component dimensions (mm)
0.2 x 0.4
Ersa GmbH
Operating instructions HR 550 XL EN 3BA00247-01 | Rev. 1