7 | Tutorial – Soldering or desoldering a component
Shielding heat sensitive components
7.4 Shielding heat sensitive components
2
1
a) Use reflective strip and/or an adequate air deflector for shielding purposes.
b) To avoid material damage when installing air baffles, make sure that the air
baffle does not touch the pipette and the soldering nozzle.
c) Fit the back lugs of the air baffle (1) into the bottom plate of the heating head
(2) from behind. Then press the air baffle upwards on its front side.
Ersa GmbH
Operating instructions HR 550 XL EN 3BA00247-01 | Rev. 1
123 / 157