2 | Technical data
Heating system
Designation
Max. component dimensions (mm)
70 x 70
Type operating distance above (mm)
35 – 60 to top heating
35 to bottom heating
Clearance below (mm)
35
2.5 Heating system
Bottom radiator
Designation
Heating type
Medium wave, infrared, reactive
ceramic heating elements
Radiator cassette dimensions (width x
depth, mm)
530 x 530
Number of heating zones
8
Rated power (kW) at 230 V
6.4 (8 x 0.8)
Top radiator
Designation
Heating type
Hybrid radiators, ceramic heating ele-
ments, medium wave, infrared, with hot
air
Component handling
Built-in pipette, motorised
Dimensions (width x depth, mm)
80 x 80
Rated power (kW) at 230 V
0.9 hot air and 0.9 infrared
Aperture adapter (mm)
30 x 30, 45 x 45
Temperature sensors
Designation
Sensor type
Digital, non-contact infrared sensor
(pyrometer)
Inputs for k-type thermocouples*
3
*An AccuTC is included in the scope of delivery.
2.6 Axis system
Designation
Type
Precision rail guide with step motors
Axes
Z heating head, Z pipette
Repeat accuracy (µm)
± 25
Control unit
Bottom heating X/Y-axis and pipette ro-
tation
2.7 Pneumatics
Designation
Maximum inlet pressure (bar, oil-free)
6
Ersa GmbH
Operating instructions HR 550 XL EN 3BA00247-01 | Rev. 1
20 / 157