Descriptions of Parameters
System Parameters
5-31
Clock
Set Clock to
Internal
(the default) to use the PC2Õs internal MIDI clock for arpeggiation, and to
control synchronization with external MIDI equipment. Set Clock to
External
when you want
the PC2 (including the arpeggiator) to synchronize with a MIDI Clock signal from an external
source.
Transmit Clock
This parameter determines whether the PC2 sends its internal MIDI clock signal to its MIDI Out
port. This parameter is irrelevant if the Clock parameter has a value of
External
. There are three
possible values:
Touch
Sets the keyboard sensitivity for the entire PC2, somewhat like the Vel Scale parameter for
individual programs and setups (like Vel Scale, the value for the Touch parameter also affects
notes that get sent via MIDI). There are seven possible values:
A value of
Linear
(the default) is the standard, unaltered level of keyboard sensitivity. Values of
Light1
Ð
Light3
are for players who have a light touchÑthat is, you can play more lightly and
still get the same attack-velocity values.
Light1
is more sensitive than
Linear
, and
Light3
is the
most sensitive.
Values of
Hard1
Ð
Hard3
are for players who have a heavier touchÑthat is, you can play harder
and still get the same attack-velocity values.
Hard1
is less sensitive than Linear, and
Hard3
is the
least sensitive.
Change Setups (Chg Setups)
Determines what the PC2 does when you select a setup.
Immediate
The newly-selected setup becomes active as soon as you select it. Any notes being held by the
PC2 (or by Kurzweil instruments receiving MIDI from the PC2) continue with their normal
decays. Non-Kurzweil MIDI slaves may cut off notes as soon as the PC2Õs setup changes.
Keys Up
Default value. The newly-selected setup becomes active only after youÕve physically released all
keys (notes held with Sustain or other MIDI Controllers donÕt delay the change). Until you
Off
The PC2 doesnÕt transmit its internal clock signal.
On
The PC2 always transmits its internal clock signal to its MIDI Out port.
Seq
Default value. The PC2 transmits its internal clock signal to its MIDI Out port only
when youÕre playing one of the demo sequences or using the arpeggiator.
1 Linear
5 Hard1
2 Light1
6 Hard2
3 Light2
7 Hard3
4 Light3