Setup Mode
Controllers
7-21
Switch Controllers
See
Switch Controller Parameters
on page 7-30
for information on each parameter.
Physical Controller
Setup Editor
Page
Parameter:Values
Footswitches 1, 2, and 3
FT SW1,
FT SW2,
FT SW3
SwType: Toggle, Momentary, Note Toggle,
Note Momentary
Destination: Control Destination List
On Value: None, 0 to 127
Off Value: None, 0 to 127
Entry Value: None, Off, On
Exit Value: None, Off, On
Arp and SW switches
ARP SW,
SWITCH
(same as Footswitches)
Programmable switches 1 to 8
SWPRG1,
SWPRG2,
SWPRG3,
SWPRG4,
SWPRG5,
SWPRG6,
SWPRG7,
SWPRG8
(same as Footswitches)
Table 7-3 Switch Controllers
The Controller Destination List
The table below contains the available values for the Destination parameter for each controller, in
scrolling order. Note that the PC3A has destinations with Controller Numbers greater than
127—there are 128 MIDI Controllers, as dictated by the MIDI spec. Any data sent to destinations
with a Controller number outside of the MIDI range (i.e., more than 127) are sent as a PC3A-
specific protocol, and are thus not sent as MIDI data, and not sent through MIDI Out.
Controller
Number
Corresponding
Destination
Name
Description
0
OFF/Bank
By default, when you enter
0
or
Clear
for the Destination
parameter, the destination will be assigned to
OFF
. To select
Bank
as the destination, use the Alpha Wheel or
-/+
buttons.
1
MWheel
Default assignment for Mod Wheel
2
Breath
Default assignment for Breath Controller
3
MIDI 03
4
Foot
Default assignment for CC Pedal 2
Table 7-4 Controller Destination List