background image

E

LECTRICAL SPECIFICATIONS :

DC VOLTAGE

Range

Resolution

400   mV

4          V

40        V

400      V

1000    V

0.1     mV

1        mV

10      mV

100    mV

1           V

Accuracy

± (0.8% rdg + 2 dgt)

Input Impedance : 10M
Overload Protection : 400mV range 500V Rms
Other ranges 1000VDC or 750VAC Rms

W

AC VOLTAGE

Range

400    mV         
4           V
40         V
400       V

Resolution

0.1     mV
1        mV
10      mV
100       V

Accuracy

±(1.8% rdg + 5dgts)

750       V

1          V

±(1.5% rdg + 3dgts)

Input Impedance : 10M
Overload Protection : 400mV range 500V Rms
Other ranges 1000VDC or 750VAC Rms

W

AC CURRENT          (Avg. Sine Wave)

Input Voltage Drop :  0.8V
Overload Protection : Fast Fuse 0.8A/250V 
& 10A/250V

£

Accuracy

±(1.8% rdg + 3dgts)

±(2.0% rdg + 3dgts)

Resolution

0. 1     

m

A

1         

m

A

0.01    A

m

0.1      A

m

Range

400    A

m

4000 

m

A

40    mA

400  mA

AC±(2.5% rdg + 5dgts)

0.01      A

10       A

4

GENERAL SPECIFICATIONS : 

                              

Display

:

3  digit LCD. Maximum
reading 3999 with
automatic sign and
function annunciators.

Overrange 

:

Highest digit of (1) or (-1)

indication

is displayed.

 

Low battery 

:

The “         ” sign is displayed
when the battery voltage drops
below the operating Voltage. 

Measurement  

:

2.5 measurements 

rate

per Second, nominal.

 

Operating 

:

0°C to + 50°C, <70% RH. 

temperature

Storage 

:

-20°C to 60°C, <80% RH

temperature

with battery removed.

Accuracy

:

Accuracy specifications at
23 ± 5°C less than 75% RH.

Power 

:

Single 9 V Battery

Dimension

:

151mm (L),70mm(W),38mm(H

 Weight

:

Approx (210 grams)
including battery

  

Alarm

:

Buzzer Sounds when the
lead is connected to the
wrong input terminals.

Accessories

:

Test leads,Operators Manual, 
Battery, Carrying Case,  
Protective Holster, Temperature 
Probe.

¾

- +

3

Summary of Contents for 207-MK-1

Page 1: ...ontact infrared Thermometer Thermo Hygrometer Thermo Anemometer Wood Moisture Meter Distance Meter Calibrators Gas Analysers Panel meters Battery Testers Digital Hand Held Temperature Indicators Digit...

Page 2: ...vironment you can easily exceed those ratings The best way to avoid damage is to use a clamp meter or to connect a clamp attachment to your DMM To prevent excess current from flowing through your mete...

Page 3: ...nging Digital Multimeter Model 207 MK1 T hereafter referred to as the Meter is a 3 digits Multimeter with steady operations and highly reliable hand held measuring instrument having different measurem...

Page 4: ...1 A m Range 400 A m 4000 m A 40 mA 400 mA AC 2 5 rdg 5dgts 0 01 A 10 A 4 GENERAL SPECIFICATIONS Display 3 digit LCD Maximum reading 3999 with automatic sign and function annunciators Overrange Highes...

Page 5: ...1 C Accuracy 0 1 rdg 4dgts Resolution 0 01 Hz Range 9 999 Hz FREQUENCY 0 001 MHz 9 999 MHz Overload Protection 250 V Rms Sensitivity 0 7V Rms 6 DC CURRENT Accuracy 1 2 rdg 2dgts AC 2 rgd 3dgts DC 1 5...

Page 6: ...o the following rules n Before using the Meter inspect the case Do not use the Meter if it is damaged or the case or part of the case is removed Look for cracks or missing plastic Pay attention to the...

Page 7: ...nal button operations 10 V W CAP NPN PNP C m A mA 10A CE OFF OFF Hz SELECT RANGE HOLD Hz DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX VW mA COM 10A 207 MK 1 T 399 9 E E B C The Multimeter Structure se...

Page 8: ...display is not on otherwise false readings may be provided n Pay extra attention to the symbol which is located besides the input terminals of the Meter before carrying out measurement A DC VOLTAGE ME...

Page 9: ...uit voltage between terminals and ground is greater than 60V DC or 30V rms If the fuse burns out during measurement the Meter may be damaged or the operator himself may be hurt 14 Caution n If the val...

Page 10: ...ion and range for the measurement When the testing leads are connected to the current terminals do not parallel them across any circuit The AC current measurement has 5 measurement positions on the ro...

Page 11: ...range for the measurement When the testing leads are connected to the current terminals do not parallel them across any circuit The DC current measurement has 5 measurement positions on the rotary sw...

Page 12: ...10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C Capacitor 20 Note n The test leads can add 0 1W to 0 3W of error to the Resistance measurement To obtain precision readings in lo...

Page 13: ...DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C 22 Caution n Never connect high voltage to the input sockets with the switch in Capacitance range n Using Capacitan...

Page 14: ...value Figure 11 Red Black V W CAP NPN PNP C m A mA 10A CE OFF OFF Hz SELECT RANGE HOLD Hz DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C 24 The frequency measure...

Page 15: ...ads and the circuit under test Testing for Continuity To test for continuity connect the Meter as below 1 Insert the red test lead into VW terminal and the black test lead into the COM terminal 2 Set...

Page 16: ...thorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered n...

Reviews: