background image

1.  Set function knob to the proper AC A Range. Press the trigger to open the  jaws and clamp on to one conductor only. 

     The transformer jaws pick up the AC current flowing through the conductor.

2.  When only the figure "1" displayed, it indicates over range situation and the higher range has to be selected.

3.  The reading will be indicated on the display.

5. OPERATING INSTRUCTION :

5.1 Measuring Current:

(1) Jaws should he completely closed while taking a reading.

(2) The most accurate reading will be obtained by the conductor across center of the transformer jaws.

NOTE:

5.2  AC Voltage Measurement :

1. Set the function knob to the AC V range.

2. Connect the black test lead to the "COM" terminal and red test lead to the "V/

W

" terminal. You can now place the test probes to the 

     source or load under measurement.

3. When only the figure "1" is displayed, it indicates over range situation disconnect the test leads immediately to avoid damage to

     the meter.

5.3  DC Voltage Measurement :

1. Set the function knob to the DC V range.

2 Connect the black test lead to the "COM' terminal and red test lead to the "V/

W

" terminal. You can now place the test probes to the 

    source or load under measurement.

3. The polarity of red lead connection will be indicated along with the voltage value.

4. When only the figure "1" is displayed, it indicated over range situation disconnect the test leads immediately to avoid damage to

     the meter

5.4  Resistance Measurement :

1.  Set the function knob to the “   20000

W

” range

2.  Connect the black test lead to the “COM” terminal and red test lead to the V/

W

 terminal.

3.  Verify that the power to the circuit under test is off. Connect test lead to the circuit to make measurement.

NOTE:

 If the resistance being measurement exceeds, the maximum value of the range selected or the input is not connected, 

            an over range indication "1' will be displayed

WARNING

To avoid electrical shock, hazard or damage to the meter, do not attempt to measure voltage that might exceed DC 600V.

To avoid electrical shock, hazard or damage to the meter, do not attempt to measure voltage that might exceed AC 600V RMS.

(1)  Attempting resistance or continuity measurements on live circuits can cause electrical shock, damage to the meter and damage 

      to the equipment under test.

(2)  Resistance measurement must be made on de-energized circuit.

5.5  Continuity Test

1.  Set the function knob to the “   20000

W

” range.

2.  Connect the black test lead to the "COM" terminal and red test lead to the "V/

W

" terminal.

3.  Connect the test probes across two points of the circuit under testing. If continuity exists BUZZER will sound.

6.  Maintenance :

Maintenance consists of periodic cleaning and battery replacement. The exterior of the meter can be cleaned with a dry clean cloth to 

remove any oil, grease. Never use liquid solvents or abrasives

Replacing Battery :

When the meter displays the sign "      ", the battery must be replaced to maintain proper operation. Remove the battery cover of case.

replace the exhausted battery with new one.

To avoid electrical chock, disconnect the test leads and any input signals before replacing the battery. Replace only with same type of battery.

WARNING

17, Bharat  Industrial  Estate, T.  J . Road,  Sewree (W), Mumbai - 400015. INDIA

Sales Direct:

 (022)24156638        

Tel.:

(022) 24124540, 24181649       

Fax: 

(022) 24149659 

E-mail :

 kusam_meco@vsnl.net,    

Website :

 www.kusamelectrical.com

®

®

AN ISO 9001:2015 COMPANY

Summary of Contents for KM 1001

Page 1: ... notice G 17 Bharat Industrial Estate T J Road Sewree W Mumbai 400 015 INDIA Sales Direct 022 24156638 Tel 022 24124540 24181649 Fax 022 24149659 Email kusam_meco vsnl net Website www kusamelectrical com KM 1001 Digital Clampmeter is completely portable 3 Digit LCD display meter This Clampmeter is designed for us in the Laboratory Field servicing at home under any circumstance where high current m...

Page 2: ... scale to be measured is unknown set the range selector at the highest position Before rotating the selector to change function disconnect test leads from the circuit under testing Never perform resistance measurements on live circuits When the jaw is opened and while the conductor is under testing our fingers must keep behind the barriers indicator Never ground yourself when taking electrical mea...

Page 3: ...hat the power to the circuit under test is off Connect test lead to the circuit to make measurement NOTE If the resistance being measurement exceeds the maximum value of the range selected or the input is not connected an over range indication 1 will be displayed WARNING To avoid electrical shock hazard or damage to the meter do not attempt to measure voltage that might exceed DC 600V To avoid ele...

Page 4: ...AM MECO This warranty does not apply for damaged Ic s fuses disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling This warranty extends only to the original buyer or end user customer of a KUSAM MECO authorized dealer KUSAM MECO authorized d...

Reviews: