-7-
®
®
AC CURRENT (Clamp-On)
Range
Resolution
1)2)3)
Accuracy
40.00 A
400.0 A
600 A
10 mA
100 mA
1 A
± (1.5% rdg + 8 dgts)
1)
Induced error from adjacent current carrying conductor : 0.05/A
2)
Specified accuracy is from 1% to 100% of range and for
measurements made at the jaw center. When the conductor is not
positioned at the jaw center, position errors introduced are :
Add 2% to specified accuracy for measurements made BEYOND
jaw marking lines (toward jaw opening)
3)
Add 8d to specified accuracy @ reading <10% of range.
50Hz / 60Hz
OHMS
Range
Resolution
1)2)3)
Accuracy
400.0
W
4.000 k
W
40.00 k
W
400.0 k
W
4.000 M
W
40.00 M
W
0.1
W
1
W
10
W
100
W
1 k
W
10 k
W
± (0.8% rdg + 8 dgts)
Open Circuit Voltage :
0.4VDC typical
± (0.6% rdg + 4 dgts)
± (2.0% rdg + 4 dgts)
± (1.0% rdg + 4 dgts)
MAX HOLD
Specified accuracy ± 50 digits for changes > 25ms in duration.
AUDIBLE CONTINUITY TESTER
Audible threshold : between 5 and 120 .
WW
DIODE TESTER :
Open Circuit Voltage : <1.6 VDC
Test Current (Typical) : 0.25mA
-8-
®
®
CAPACITANCE
Range
1)
Resolution
2)3)
Accuracy
500.0 nF
5.000
m
F
50.00
m
F
100 pF
1 nF
10 nF
100 nF
1
m
F
± (3.5% rdg + 6 dgts)
1)
Additional 50.00nF range accuracy is not specified.
2)
Accuracies with film capacitor or better
3)
Specified with battery voltage above 2.8V
(approximately half full battery).
Accuracy decreases gradually to 12% at low battery warning
voltage of approximately 2.4V.
500.0
m
F
3000
m
F
Hz FREQUENCY
Function
Sensitivity
(Sine RMS)
Range
Display Counts :
5000
Best resolution :
0.001Hz
Accuracy :
0.5% + 4d
400.0 mV
4.000 V
4.000 V
40.00 V
400.0 V
600 V
400.0 A
350 mV
1 V
32 V
100 V
500 V
60 A
10Hz ~ 2kHz
10Hz ~ 5kHz
10Hz ~ 100kHz
10Hz ~ 10kHz
10Hz ~ 5kHz
40Hz ~ 400Hz
Summary of Contents for KM 111M
Page 4: ...7 7 3 4 Average KM 111M True RMS KM112M...
Page 8: ...11 12...
Page 9: ...13 14...
Page 10: ...15 16...
Page 11: ...17 16 18...