background image

-7-

®

®

AC CURRENT (Clamp-On)

Range

Resolution

1)2)3)

Accuracy

40.00     A

400.0     A

600        A

10      mA

100    mA

1           A

± (1.5% rdg + 8 dgts)

1)

 Induced error from adjacent current carrying conductor : 0.05/A

2)

 Specified accuracy is from 1% to 100% of range and for

   measurements made at the jaw center.  When the conductor is not
   positioned at the jaw center, position errors introduced are :
        Add 2% to specified accuracy for measurements made BEYOND
        jaw marking lines (toward jaw opening)

3)

 Add 8d to specified accuracy @ reading <10% of range.

50Hz / 60Hz

OHMS

Range

Resolution

1)2)3)

Accuracy

400.0     

W

4.000   k

W

40.00   k

W

400.0   k

W

4.000  M

W

40.00  M

W

0.1    

W

1       

W

10     

W

100   

W

1     k

W

10   k

W

± (0.8% rdg + 8 dgts)

Open Circuit Voltage :

 0.4VDC typical

± (0.6% rdg + 4 dgts)

± (2.0% rdg + 4 dgts)

± (1.0% rdg + 4 dgts)

MAX HOLD

Specified accuracy ± 50 digits for changes > 25ms in duration.

AUDIBLE CONTINUITY TESTER

Audible threshold : between 5  and 120 .

WW

DIODE TESTER :

Open Circuit Voltage : <1.6 VDC
Test Current (Typical) : 0.25mA

-8-

®

®

CAPACITANCE

Range

1)

Resolution

2)3)

Accuracy

500.0  nF

5.000  

m

F

50.00  

m

F

100   pF

1       nF

10     nF

100   nF
1       

m

F

± (3.5% rdg + 6 dgts)

1)

 Additional 50.00nF range accuracy is not specified.

2)

 Accuracies with film capacitor or better 

3)

 Specified with battery voltage above 2.8V 

   (approximately half full battery).
   Accuracy decreases gradually to 12% at low battery warning 
   voltage of approximately 2.4V.

500.0  

m

F

3000   

m

F

Hz FREQUENCY

Function

Sensitivity
(Sine RMS)

Range

Display Counts :

 5000

Best resolution :

 0.001Hz

Accuracy :

 0.5% + 4d

400.0 mV

4.000    V

4.000    V

40.00    V

400.0    V

600       V

400.0    A

350  mV

1         V

32       V

100     V

500     V

60       A

10Hz ~ 2kHz

10Hz ~ 5kHz

10Hz ~ 100kHz

10Hz ~ 10kHz

10Hz ~ 5kHz

40Hz ~ 400Hz

Summary of Contents for KM 111M

Page 1: ...Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Mete...

Page 2: ...nt Even if you correctly insert your clamp meter in to the circuit you can still damage your meter Don t try to measure current in excess of your meter s capacity Check the current capacity of the Cla...

Page 3: ...c Per IEC61010 Overvoltage Installation Category Overvoltage Category II Equipment of is energy consuming equipment to be supplied from the fixed installation Overvoltage Category II Note Examples inc...

Page 4: ...7 7 3 4 Average KM 111M True RMS KM112M...

Page 5: ...nal 1000MW for 400 0mV range AC VOLTAGE 50Hz 500Hz Range Resolution Accuracy 4 000 V 40 00 V 400 0 V 600 V 1 mV 10 mV 100 mV 1 V 1 5 rdg 5 dgts 2 0 rdg 5 dgts CMRR 60dB DC to 60Hz Rs 1kW Input Impedan...

Page 6: ...2 0 rdg 4 dgts 1 0 rdg 4 dgts MAX HOLD Specified accuracy 50 digits for changes 25ms in duration AUDIBLE CONTINUITY TESTER Audible threshold between 5 and 120 WW DIODE TESTER Open Circuit Voltage 1 6...

Page 7: ...9 10 CAUTION Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to determine proper meter functioning...

Page 8: ...11 12...

Page 9: ...13 14...

Page 10: ...15 16...

Page 11: ...17 16 18...

Page 12: ...hority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective product which is retu...

Reviews: