background image

®

11

Line Frequency 

60mV

6V

60V

600V

VFD 600V

VFD1000V

600

A

60mA

1000V

5V

50mV

10V

50V

50V

500V

500V

500

A

50mA

10Hz - 50kHz

10Hz - 50kHz

10Hz - 50kHz

10Hz - 1kHz

10Hz - 1kHz

10Hz - 1kHz

10Hz - 5kHz

10Hz - 5kHz

6A, 10A

8A

50Hz - 1kHz

10Hz - 1kHz

Range

Function

Sensitivity (Sine RMS)

600mV

6000

A

600mA

12

®

1. 3-5/6 digits 6000 counts 

LCD display

2.  Push-buttons for special 

functions & features

3. Selector to turn the Power 

On  or  Off  and  Select  a 
function

4. Input Jack for 10A (20A 
    for 30sec) current 
    function

5. Input  Jack  for  all  functions 

EXCEPT A, mA & A current
 functions 

6. Common (Ground 

reference) Input Jack for 
all functions

7. Input Jack for A and mA 

current function 

V. PRODUCT DESCRIPTION :

Note :

 Top of the line model is used as representative for illustration

purposes.   Please   refer   to  your  particular  model   for  function 
availability.

True RMS :

RMS (Root-Mean-Square) is a term used to describe the effective 
or equivalent DC value of an AC signal. True RMS is the term which 
identifies a DMM that responds accurately to the effective RMS 
value regardless of the waveforms such as: square, sawtooth, 

 

Summary of Contents for KM 233

Page 1: ...Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function...

Page 2: ...TABLE OF CONTENTS TITLE PAGE NO I Safety II Cenelec Directives III Special Features IV General Specifications V Electrical Specifications VI Product Description VII Maintenance VIII Test Certificate I...

Page 3: ...4mm for CAT III CAT IV ratings Refer to the category markings on your probe assemblies as well as on the add on accessories like detachable Caps or Alligator Clips if any for applicable rating changes...

Page 4: ...004 108 CU and RoHS directive 2011 65 EU 04 IV GENERAL SPECIFICATIONS Sensing True RMS sensing Display 3 5 6 digits 6 000 counts Update Rate 5 per second nominal o o Operating Temperature 10 C to 45 C...

Page 5: ...User s manual Optional Purchase Accessories BMH 01 magnetic hanger BMP 25x soft carrying pouch ELECTRICAL SPECIFICATIONS Accuracy is given as of reading digits number of digits or o o otherwise specif...

Page 6: ...0 3 rdg 2dgts 0 4 rdg 2dgts 0 4 rdg 2dgts 0 2 rdg 2dgts 60 00mV 600 0V 1000V 60 00V 600 0mV 6 000V Range Resolution 10 V 100 V 10 V 100 V 10 V 100 V 1 mV 10 mV 100 mV 1 V 08 BeepLit Continuity Tester...

Page 7: ...00M 100 mV 1 V 100 mV 1 V 100 m 1 10 100 1 k 10 k 10 DC Current AC Current Range Range Burden Voltage Burden Voltage Accuracy Accuracy 600 0 A 600 0 A 6000 A 6000 A 60 00mA 60 00mA 600 0mA 600 0mA 6...

Page 8: ...nput Jack for 10A 20A for 30sec current function 5 Input Jack for all functions EXCEPT A mA A current functions 6 Common Ground reference Input Jack for all functions 7 Input Jack for A and mA current...

Page 9: ...oning AutoV LoZ mode AutoV automatically selects measurement function of DCV or ACV based on their input levels via the test leads The input also provides a low ramp up impedance LoZ to drain ghost vo...

Page 10: ...t is recommended to first measure the signal voltage or current level and activate Hz function in that range to get the most appropriate trigger level If the Hz reading becomes unstable select lower s...

Page 11: ...ny measurement Large value capacitors should be discharged through an appropriate resistance load A mA and A Current Press SELECT button momentarily to toggle between DC and AC Last selection will be...

Page 12: ...e over 165 oF 74 oC at photocell 19 CAUTION Using resistance and continuity function in a live circuit will produce false results and may damage the instrument In many cases the suspected component mu...

Page 13: ...feature 21 Electric Field EF Detection Press the EF button momentarily to toggle EF Detection feature The meter displays EF H when it is ready If it is too sensitive for your applications press Level...

Page 14: ...n zero readings for Hz function 5 Electric field signal present for EF function 6 Significant movement indication as in Phase Rotation functions 23 Relative Zero mode Relative Zero allows the user to...

Page 15: ...2 for A current input 11A 1000V DC AC IR 20kA F fuse or better Dimension 10 x 38mm 26 MUMBAI TEST CERTIFICATE TRMS DIGITAL MULTIMETER This Test Certificate warrantees that the product has been inspect...

Page 16: ...aminated or damaged by accident or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have n...

Reviews: