Press  and  hold  the  

SELECT

 button  while turning the meter on to 

temporarily  disable  the  Auto-Power-Off  (APO)  feature.  Turn  the 

rotary switch OFF and then back on to resume.

Auto-Power-Off (APO)

The Auto-Power-Off  (APO)  mode  turns  the  meter  off  automatically 

to  extend  battery  life  after  approximately  34  minutes  of  no  rotary 

switch or push button  operations.  To wake up the meter from APO,

press  the 

SELECT

  button  momentarily  and  release  or  turn  the 

rotary switch OFF and then back on. Always turn the rotary switch 

to the OFF position when the meter is not in use.

Disabling Auto-Power-Off

 MAINTENANCE

To  avoid  electrical  shock,  disconnect  the  meter  from  any  circuit, 
remove the test leads from the input jacks and turn OFF the meter 
before  opening  the  case.  Do  not  operate  with  open  case.

WARNING

If  the  instrument  fails  to  operate,  check  batteries  and  test  leads 
etc., and  replace  as necessary. Double check operating procedure 
as described in this user's manual.

Trouble Shooting

If the instrument voltage-resistance input terminal has subjected to 

high  voltage  transient  (caused  by  lightning  or  switching  surge  to 

the  system  under  test)  by  accident  or  abnormal  conditions  of 

operation, the protective impedance components in series might be 

 

The meter uses standard 1.5V AA Size (IEC LR6) battery X 2

Loosen the 2 captive screws from the battery cover case. Lift the 

battery cover case. Replace the batteries. Replace battery cover

case. Re-fasten the screws.

Battery Replacement

Periodically wipe the case with a damp cloth and mild detergent; do

not  use  abrasives  or  solvents.  If  the  meter  is  not  to  be  used  for 

periods of longer than 60 days, remove the batteries and store them 

separately. 

Cleaning and Storage

- 27 -

blown  off  (become  high  impedance)  like  fuses  to  protect  the  user 

and the  instrument.  Most  measuring functions through this terminal 

will then be open circuit. 

Summary of Contents for KM 2777

Page 1: ...otherwise specified Power supply Standard 1 5V AAA Battery x 2 Power Consumption Typical 14mA for Current function 5 2mA for others APO Timing Idle for 34 minutes APO Consumption 10m A typical Dimens...

Page 2: ...olution Range 4 0 rdg 5dgts 2 1 Accuracy 600 0 m F 2000 m F 1 Accuracies with film capacitor or better 2 Temperature Coefficient 0 25 x specified accuracy C 0 C 18 C or 28 C 40 C 10 pF 100 pF 1 nF 10...

Page 3: ...faster than their rated life 2 Circuit breakers to trip prematurely 3 Fuses to blow 4 Neutrals to overheat due to triplen harmonics present on the neutral 180Hz 5 Bus bars and electrical panels to vib...

Page 4: ...00 0 433 0 416 3 8 2 000 0 331 0 243 26 5 2 000 0 242 0 130 46 2 One limitation to making true RMS measurements is crest factor and you should consider crest factor when making AC measurements Crest f...

Page 5: ...e Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Batte...

Page 6: ...AC DC TRMS Clamp On Multimeter with VFD EF Detection PC Interface MODEL KM 2777...

Page 7: ...e building wiring It applies both to plug connected equipment and to PERMANENTLY CONNECTED EQUIPMENT The meter protection rating against the users is double insulation per IEC EN61010 1 2nd Ed UL61010...

Page 8: ...st leads connectors and probes for damaged insulation or exposed metal before using the instrument If any defects are found replace them immediately Only use the test lead provided with the equipment...

Page 9: ...specified 04 Power supply Standard 1 5V AAA Battery x 2 Power Consumption Typical 14mA for Current function 5 2mA for others APO Timing Idle for 34 minutes APO Consumption 10mA typical Dimension 264...

Page 10: ...s 40Hz 50Hz 60Hz 400Hz 200 0 A 0 500 A 500 1000 A 3 0 rdg 5dgts 3 5 rdg 5dgts 1000 2000 A Unspecified 100 mA 1 A 1 A 100 mA 1 A 1 A 1 A 06 DC ACA CURRENT Clamp on 1 2 Accuracy Resolution Range True RM...

Page 11: ...1 2 rdg 5dgts Input Impedance 10MW 50pF nominal 1 mV 10 mV 100 mV 1 V 08 VFD_ ACV with Low Pass Filter 6 000 V 4 rdg 80dgts 60 00 V 600 0 V 1000 V 1 Accuracy Resolution Range 10Hz 20Hz 20Hz 200Hz 2 20...

Page 12: ...pacitor or better 2 Temperature Coefficient 0 25 x specified accuracy C 0 C 18 C or 28 C 40 C 10 pF 100 pF 1 nF 10 nF 100 nF 1 mF 11 TM AUTOCHECK _DCV Accuracy Resolution Range TM AutoCheck Lo Z DCV T...

Page 13: ...6 000 V 1 5 rdg 5dgts 60 00 V 600 0 V 1000 V 1 Accuracy Resolution Range 50Hz 60Hz 1 mV 10 mV 100 mV 1 V TM AUTOCHECK _ACV TM AutoCheck Lo Z ACV Threshold 1 5V 50 60Hz nominal TM AutoCheck Lo Z ACV i...

Page 14: ...w trigger for opening the clamp jaw 15 TM This innovative AutoCheck feature automatically selects Hz measurement function of ACV DCV or Resistance based on the input via test leads CAUTION Before and...

Page 15: ...on high voltage hard signals LoZ displays on the LCD to remind the users of being in such low impedance mode Peak initial load current while probing 1000VAC for example can be up to 566mA 1000V x 1 41...

Page 16: ...around conductor s of only one single pole of a circuit for load current measurement Make sure the jaws are completely closed or else it will introduce measurement errors Enclosing conductor s of more...

Page 17: ...900V A reading higher than that indicates a leaky diode defective A zero reading indicates a shorted diode defective An OL indicates an open diode defective Reverse the test leads connections reverse...

Page 18: ...o use a plug adapter bkb32 optional purchase with banana pins to type k socket to adapt other type k standard mini plug temperature probes F C 1 SELECT 23 In Voltage or Current function press the EF b...

Page 19: ...ounds energized conductors It is ideal for tracing live wiring connections locating wiring breakage and to distinguish between live or earth connections Probe Contact EF Detection For more precise ind...

Page 20: ...heck batteries and test leads etc and replace as necessary Double check operating procedure as described in this user s manual Trouble Shooting If the instrument voltage resistance input terminal has...

Page 21: ...oducts to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or...

Reviews: