MAINTENANCE

Cleaning :- 

Periodically wipe the case with a damp

cloth do not use abrasives or solvents.

Calibration :- 

Calibrate your instrument once a year

to   ensure   that   it   performs    according   to   its 
specifications.

7)  Do  not  use  the  AC  power  adapter  in  a  high 
     temperature  or  wet  place.

8)  Please make the AC power adapter avoid a strong
     bump.

9)  It  is  normal  when  the  AC  power  adapter  make 
     some noise in use.

1)  Please use the original AC power adapter, using
    other  AC  power  adapter  may  damage  your 
     instrument.

2) The AC power adapter can only be used indoors.

4)  Do not use the AC power adapter in other equipment 
     except this instrument.

5)  In use, it is a normal phenomenon that the AC power
     adapter will be hot.

6)  Do not demolish the AC power adapter. Otherwise, it
     may be dangerous

WARNING:

3)  Please  plug  the  AC  power  cord  into  an  electrical
      outlet  first  and  then  firmly  insert  DC  plug  into  DC 
     input end in the right of the meter. When unplugged, 
     firstly pull out the DC plug perpendicular to DC input 
    end and then unplug the AC plug from the electrical 
     outlet.

Figure 14

GUARD

GUARD

L

CUR

L

POT

H

POT

H

CUR

OPEN

Note  :  To  get  the  better  accuracy,  when  using 
L

CUR

/L

POT

/  H

POT

/H

CUR

/  terminal  measured  with  the 

alligator    clip-testing  lines,  Please  insert  the  open 
soket to the  square terminals (shown in figure 14).

If there are some changes in accessories, please 
refer to the real products as standard.

ACCESSORIES

=

  User manual.                                

=

  AAA batteries

=

  Shielding clip line

=

  Kelvin 4-terminal measure line

=

  Short socket

=

  USB line (USB model only)

=

  PC-Link software CD 

     (USB model only)

One piece
Six piece
One piece
One piece
One piece
One piece
One piece

Turn  off  the  power  of  the  instrument.  When  you 
change the battery, and screw off the breechblock 
on  the  battery  cabinet  cover,  then  take  off  it  and 
replace with fresh battery.

Replacing the Battery :-  

Please   change   the 

battery when the battery symbol         is less than 
one  segment.

22

Summary of Contents for KM 520B

Page 1: ...meter Wood Paper Grain Moisture Meter Distance Meter Network Cable Tester Digital Hand Held Temperature Indicators Digital Lux Meter Thermal Imaging Camera Power Factor Regulator Maximum Demand Contro...

Page 2: ...o turn off the instrument when replacing the battery or DC power adapter Although the instrument has a protection for shocks inputing dc voltage or current will still damage the instrument The capacit...

Page 3: ...20nF 20mF 2000pF 2mF 200pF 200m F 200pF 20m F 200W 200MW 20W 200MW 20W 20MW 20W 2MW C R DCR D Q q Test Level Range mode Equivalent circuit 0 6 Vrms Auto and Hold Parallel and Series 4 Specifications C...

Page 4: ...ity factor ESR equivalent series resistance Rp equivalent series parallel resistance q phase angle 6 Explanation on Front Panel The front panel is shown as figure 1 1 Mini USB interface Connect with P...

Page 5: ...y When sorting mode is active press SETUP key to modify the reference value range and the tolerance setting sequentially 11 SER PAL key Used to select series and parallel mode 12 FREQ key Press FREQ k...

Page 6: ...ay is quality factor Q C D Capacitance measurement the parameter on sub display is dissipation factor D R Resistance measurement DCR DC resistance measurement mode L C R measurement readings can be po...

Page 7: ...bers the current readings on primary display called initial value when pressing the REL key and 12 b When using insert the black and red testing lines with alligator clip into the terminal and termina...

Page 8: ...gs to the component type press FUNC key to select L C or R measurement mode 2 Insert the standard component into the input therminal Press SORTING key to enter into the sorting mode and the Sorting sy...

Page 9: ...nce setting mode automatically 6 When setting the tolerance press D Q ESR key SER PAL key to select tolerance range 0 25 0 5 1 2 5 10 20 80 20 The default tolerance is 1 Press ENTER key to confirm 16...

Page 10: ...x Lx Cx LCUR LPOT HPOT HCUR GUARD GUARD INPUT Rx Lx Cx LCUR LPOT HPOT HCUR Figure 8 Figure 9 18 4 The default test mode is Auto LCR mode the capacitance value will be shown on primary display and the...

Page 11: ...ilable 3 The default test mode is Auto LCR mode the resistance value will be shown on primary display and the phase angle q will be shown on secondary display In Auto LCR mode the D Q ESR key SEL PAL...

Page 12: ...t and then firmly insert DC plug into DC input end in the right of the meter When unplugged firstly pull out the DC plug perpendicular to DC input end and then unplug the AC plug from the electrical o...

Page 13: ...s warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at...