background image

WARRANTY

Each  “KUSAM-MECO”  product  is  warranted  to  be  free  from 

defects  in  material  and  workmanship  under  normal  use  & 

service.    The  warranty  period  is    one  year  (12  months)  and 

begins from the date of despatch of goods.  In case any defect 

occurs in functioning of the instrument, under proper use, within 

the  warranty  period,  the  same  will  be  rectified  by  us  free  of 

charges,  provided  the  to  and  fro  freight  charges  are  borne  by 

you.

This warranty extends only to the original buyer or end-user 

customer of a “KUSAM-MECO” authorized  dealer.

This  warranty  does  not  apply  for  damaged  Ic’s,  burnt  PCB's, 

fuses,  disposable  batteries,  carrying  case,  electrodes  probes, 

cables or to any product which in “KUSAM-MECO’s” opinion, has 

been misused, altered, neglected, contaminated or damaged by 

accident or abnormal conditions of operation or handling.

“KUSAM-MECO”  authorized  dealer  shall  extend  this  warranty  on 

new and unused products to end-user customers only but have no 

authority  to  extend  a  greater  or  different  warranty  on  behalf  of 

“KUSAM-MECO”.

“KUSAM-MECO’s” warranty obligation is limited, at option, free of 

charge  repair,  or  replacement  of  a  defective  product  which  is 

returned  to  a  “KUSAM-MECO”  authorized  service  center  within 

the warranty period.

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN 

LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING 

BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY 

OR    FITNESS  FOR  A  PARTICULAR  PURPOSE.    “KUSAM-MECO”  SHALL 

NOT  BE  LIABLE  FOR  ANY  SPECIAL,  INDIRECT,  INCIDENTAL  OR 

CONSEQUENTIAL  DAMAGES  OR  LOSSES,  INCLUDING  LOSS  OF  DATA, 

ARISING FROM ANY CAUSE WHATSOEVER.

All transaction are subject to Mumbai Jurisdiction.

24

This  Test  Certificate  warrantees  that 

the  product  has  been  inspected  and 

tested in accordance with the published 

specifications.

QC

PASS

KUSAM-MECO

TEST CERTIFICATE

Multifunction LCR

MODEL NO.   __________

KM 520B

SERIAL NO. ___________

MUMBAI

DATE: ___________

ISO 9001

REGISTERED

23

Summary of Contents for KM 520B

Page 1: ...meter Wood Paper Grain Moisture Meter Distance Meter Network Cable Tester Digital Hand Held Temperature Indicators Digital Lux Meter Thermal Imaging Camera Power Factor Regulator Maximum Demand Contro...

Page 2: ...o turn off the instrument when replacing the battery or DC power adapter Although the instrument has a protection for shocks inputing dc voltage or current will still damage the instrument The capacit...

Page 3: ...20nF 20mF 2000pF 2mF 200pF 200m F 200pF 20m F 200W 200MW 20W 200MW 20W 20MW 20W 2MW C R DCR D Q q Test Level Range mode Equivalent circuit 0 6 Vrms Auto and Hold Parallel and Series 4 Specifications C...

Page 4: ...ity factor ESR equivalent series resistance Rp equivalent series parallel resistance q phase angle 6 Explanation on Front Panel The front panel is shown as figure 1 1 Mini USB interface Connect with P...

Page 5: ...y When sorting mode is active press SETUP key to modify the reference value range and the tolerance setting sequentially 11 SER PAL key Used to select series and parallel mode 12 FREQ key Press FREQ k...

Page 6: ...ay is quality factor Q C D Capacitance measurement the parameter on sub display is dissipation factor D R Resistance measurement DCR DC resistance measurement mode L C R measurement readings can be po...

Page 7: ...bers the current readings on primary display called initial value when pressing the REL key and 12 b When using insert the black and red testing lines with alligator clip into the terminal and termina...

Page 8: ...gs to the component type press FUNC key to select L C or R measurement mode 2 Insert the standard component into the input therminal Press SORTING key to enter into the sorting mode and the Sorting sy...

Page 9: ...nce setting mode automatically 6 When setting the tolerance press D Q ESR key SER PAL key to select tolerance range 0 25 0 5 1 2 5 10 20 80 20 The default tolerance is 1 Press ENTER key to confirm 16...

Page 10: ...x Lx Cx LCUR LPOT HPOT HCUR GUARD GUARD INPUT Rx Lx Cx LCUR LPOT HPOT HCUR Figure 8 Figure 9 18 4 The default test mode is Auto LCR mode the capacitance value will be shown on primary display and the...

Page 11: ...ilable 3 The default test mode is Auto LCR mode the resistance value will be shown on primary display and the phase angle q will be shown on secondary display In Auto LCR mode the D Q ESR key SEL PAL...

Page 12: ...t and then firmly insert DC plug into DC input end in the right of the meter When unplugged firstly pull out the DC plug perpendicular to DC input end and then unplug the AC plug from the electrical o...

Page 13: ...s warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at...