background image

 

                          

G7TD200G

                

 

G9TD200G                                         G9TD201G 

730

900

800

GAZ GİRİŞ

GAS INLET

652

464

GAZ GİRİŞ

GAS INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

261

321

SU GİRİŞ

WATER INLET

SU GİRİŞ

WATER INLET

122

750

150

E

B

A

C

D

G7TD200G

 

G7TD200G 

 

900

900

800

GAZ GİRİŞ

GAS INLET

646

634

GAZ GİRİŞ

GAS INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

261

321

SU GİRİŞ

WATER INLET

SU GİRİŞ

WATER INLET

122

15

0

75

0

G9TD200G

 

UDFB980G 

 

900

900

1200

523

634

GAZ GİRİŞ

GAS INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

261

321

SU GİRİŞ

WATER INLET

523

GAZ GİRİŞ

GAS INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

SU GİRİŞ

WATER INLET

122

150

750

G9TD201G

 

G9TD201G 

 

 

Summary of Contents for G7TD200G

Page 1: ...INSTRUCTION AND MAINTENANCE MANUAL TILTING BRATT PAN GAS Professionally with Professionals ...

Page 2: ...r Gas connection must be done according to national and local gas standarts Gas inlet is indicated by GAS label on the appliance body After all connections are completed check for gas leakage at joints through leakage detection device or soapy water Check whether the device is suitable for connected gas type If not see Conversion to Different Gas Types ATTENTION All adjustments and modifications t...

Page 3: ...ork Turn the gas control button 5 to position Pilot burner ignition 7 and push down At the same time press down the piezoelectric ignition button as well So the spark needed for pilot burner flame is produced Release gas control button approximately after 20 seconds Pilot burner flame will continue to burn If does not burn repeat ignition process again Ignition may be checked through flame observa...

Page 4: ...nd switches off burners CLEANING and MAINTENANCE Do not wash the device with high pressurized water You must switch off the gas and electrical connection of the device before starting to cleaning or maintenance activities Before it cools down completely wipe the device with a cloth immersed in warm soapy water at the end of each working day During cleaning the device surface do not use corrosive m...

Page 5: ...D200G G7TD200G 900 900 800 GAZ GİRİŞ GAS INLET 646 634 GAZ GİRİŞ GAS INLET ELEKTRİK GİRİŞ ELECTRICAL INLET ELEKTRİK GİRİŞ ELECTRICAL INLET 261 321 SU GİRİŞ WATER INLET SU GİRİŞ WATER INLET 122 150 750 G9TD200G UDFB980G 900 900 1200 523 634 GAZ GİRİŞ GAS INLET ELEKTRİK GİRİŞ ELECTRICAL INLET 261 321 SU GİRİŞ WATER INLET 523 GAZ GİRİŞ GAS INLET ELEKTRİK GİRİŞ ELECTRICAL INLET SU GİRİŞ WATER INLET 12...

Page 6: ... DEPTH mm 730 900 900 HEIGHT mm 900 900 900 HEAT CAPACITY KW 18 20 30 PAN CAPACITY Lt 60 80 120 GAS INLET Inch 1 2 1 2 1 2 ELECTRICAL INLET V 220 230V 50 60Hz 220 230V 50 60Hz 220 230V 50 60Hz WATER INLET Inch 1 2 1 2 1 2 GROSS WEIGHT kg 130 145 220 Fig A ...

Page 7: ...3 1 Şekil B Figure B 4 2 Figure B ...

Page 8: ...Şekil C Figure C 5 6 7 8 9 10 11 12 13 Fig C ...