All Super 30 Auto Ejects manufactured by Kussmaul Electronics Company

Inc. are warranted to be free of defects of material or workmanship. Liability is
limited to repairing or replacing at our factory, without charge, any material or
defects which become apparent in normal use within 1 year from the date the
equipment was shipped. Equipment is to be returned, shipping charges prepaid
and will be returned, after repair, shipping charges paid.

This warranty does not include normal wear and tear, pitting of the electrical

contacts, malfunction due to contamination of the mechanism, or any cracking,
breakage or damage to the connector.

Kussmaul Electronics Company, Inc. shall have no liability for damages of any

kind to associated equipment arising from the installation and /or use of the
Kussmaul Electronics Company, Inc. products. The purchaser, by the acceptance
of the equipment, assumes all liability for any damages which may result from its
installation, use or misuse, by the purchaser, his or its employees or others.

1 YEAR WARRANTY

Summary of Contents for 091-159 Series

Page 1: ...KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 FILE 091 159 XXX P65 5 23 2006 TEL in NY 631 567 0314 TOLL FREE 800 346 0857 FAX 631 567 5826 SUPER 30 AUTO EJECT AUTOMATIC SHORE LINE DISCONNECT MODEL 091 159 XXX 30 AMP ...

Page 2: ...meter Be certain that all the holes are precisely located 4 Cut out rectangular hole 5 See figure 1mounting Install weatherproof cover weatherproof cover gasket mounting plate and mounting plate gasket to super 30 using 2 8 32 x and 2 8 32 x 1 5 8 screws provided 6 Install that assembly into cut out in truck wall using 6 8 32 x self tapping screws provided INTRODUCTION The Super 30 Auto Eject is a...

Page 3: ...ector test carefully that the new connector will eject properly TEST AND OPERATION To test the unit make sure all wiring is complete Plug in connector to the Auto Eject and start the vehicle The connector should eject at this time The Super 30 Auto Eject disconnects the shoreline by extending a shaft to push the plug out of the unit A novel plug detector closes and opens the 120 volt A C Circuit a...

Page 4: ......

Page 5: ... ARE IN INCHES TOLERANCES DO NOT SCALE DRAWING DECIMALS XXX XX ANGULAR SHEET OF REV TO AC LOAD ON VEHICLE 10 AWG MINIMUM GROUND NEUTRAL LINE FIGURE 2 AC WIRING STRIP WIRES 5 FROM OUTER JACKET 3 CONDUCTOR 10 AWG MINIMUM BACK OF SUPER 30 AUTO EJECT WITH REAR PLASTIC COVER REMOVED 091 159 TORQUE SCREWS TO 16 LB IN ...

Page 6: ...N INCHES TOLERANCES DO NOT SCALE DRAWING DECIMALS XXX XX ANGULAR SHEET OF REV FIGURE 3 DC WIRING 091 159 NOTE FUSE 3 AMP FUSE FOR 12 VOLT 2 AMP FUSE FOR 24 VOLT CONNECTOR ON PC BOARD 12 VOLTS CONTINUOUS FUSE GROUND TO STARTER 3 CONDUCTOR 18 AWG WIRE PC BOARD TOP OF SUPER 30 AUTO EJECT WITH REAR PLASTIC COVER REMOVED ...

Page 7: ......

Page 8: ...SIZE DATE DWG NO 005 001 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES DO NOT SCALE DRAWING DECIMALS XXX XX ANGULAR SHEET OF REV OUTLINE DRAWING 091 159 4 190 1 010 6 210 0 330 4 676 0 250 6 123 8 874 5 356 42 0 500 1 282 4 735 1 475 ...

Page 9: ...air shipping charges paid This warranty does not include normal wear and tear pitting of the electrical contacts malfunction due to contamination of the mechanism or any cracking breakage or damage to the connector Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc...