INSTRUCTION MANUAL

2 YEAR WARRANTY

INPUT: 110-115volt, 50/60 Hz, 3.3 AMPS

Vertical Mount Only

® 

FILE: IM_091-9B-4-AD-revA.indd

REV: A

REVISED BY: THN   

DATE: 10-19-21  

MODEL #: 091-9B-4-AD

AUTO-PUMP

120 VAC

AIR COMPRESSOR SYSTEM

WITH AUTO DRAIN

170 Cherry Avenue

West Sayville, NY 11796

www.kussmaul.com

Ph: 800-346-0857

Fax: 631-567-5826

sales@kussmaul.com

Summary of Contents for AUTO-PUMP 091-9B-1-AD

Page 1: ...S Vertical Mount Only FILE IM_091 9B 4 AD revA indd REV A REVISED BY THN DATE 10 19 21 MODEL 091 9B 4 AD AUTO PUMP 120 VAC AIR COMPRESSOR SYSTEM WITH AUTO DRAIN 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com ...

Page 2: ...n A heavy duty pressure switch is ad justed to start the compressor when the system pressure drops below 75 psi and stops the compressor when 95 psi is attained The pressure switch is adjustable A moisture trap is mounted on the Auto Pump This captures any condensate which results from compressing the air The Auto Drain will automatically drain the condensate when the pump turns off Please read an...

Page 3: ... THE AUTO PUMP ROUTE OUTPUT PRESSURE LINE DOWNWARD FROM AUTO PUMP TO PERMIT MOISTURE TO DRAIN AWAY WATER IN THE PUMP OUTLET WILL INDUCE FAILURE WATER DAMAGE WILL VOID WARRANTY 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 3 ...

Page 4: ...ion of the Auto Pump air compressor system is shown below 6 Note that an external check valve is located between the compressor and the pressure switch No additional check valve is required 7 Mounttheaircompressor Connectasuitablepieceofflexibletubingfromtheoutletportof compressor to the air tank Tubing and connectors are not supplied 8 An optional Mounting Plate 091 9HP H is available to reduce a...

Page 5: ...ed line cord Wire the pump as follows Brown wire Line Blue Wire Neutral Green Yellow Wire Ground 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 5 TO MOTOR AUTO DRAIN SOLENOID POWER CORD INSTALLATION WIRING DIAGRAM PRESSURE SWITCH ...

Page 6: ...put 100 PSI Maximum Pressure Switch Set to 75 PSI Cut in 95 PSI Cut out 5 PSI Switch Differential 20 PSI Nominal Outlet Connection 1 4 NPT Female Operating Temperature 0 C to 43 C SPECIFICATION OUTLINE AUTO PUMP 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 6 ...

Page 7: ...17 64 DIA HOLE 6 PLACES Note Verify measurements before using as a template Must set print settings to Actual Size 4 75 1 75 3 50 TEMPLATE AUTO PUMP 7 6 125 3 500 Ø0 187 ...

Page 8: ...ACCESSORIES MOUNTING PLATE 091 9HP H 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 8 ...

Page 9: ...pment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of the equipment assumes all liability for any damages which may result from its installation use or misuse by the purchaser his or its employees or others 170 Cherry Avenue West Sayville NY 11796 www kussmaul com Ph 800 346 0857 Fax 631 567 5826 sales kussmaul com 9 WARR...