CAUTION

NO CONDENSATE OR

WATER MUST BE ALLOWED

TO ENTER OR ACCUMULATE

IN THE OUTPUT

  OF THE AUTO PUMP.

 ROUTE OUTPUT PRESSURE

 LINE DOWNWARD FROM

AUTO PUMP TO PERMIT

MOISTURE TO DRAIN AWAY.

CONDENSATE TRAP MUST BE

DRAINED WEEKLY

WATER IN THE PUMP

OUTLET WILL INDUCE

FAILURE !

WATER DAMAGE WILL

VOID WARRANTY

Summary of Contents for Auto-Pump 091-9HP

Page 1: ...REE 800 346 0857 FAX 631 567 5826 1 YEAR WARRANTY FILE 091 9HP PM6 5 DATE 11 17 04 KUSSMAUL ELECTRONICS CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 INPUT 120 volt 60 Hz 4 0 AMPS AUTO PUMP HP 120 VAC HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL 091 9HP ...

Page 2: ...g life and reliable operation A heavy duty pressure switch is adjusted to start the compressor when the system pressure drops below 100 psi and stops the compressor when 125 psi is attained The pressure switch is field adjustable Do not set to a pressure higher than 130 PSI A moisture trap is mounted on the Auto Pump This captures any condensate which results from compressing the air CONDENSATE MU...

Page 3: ... ENTER OR ACCUMULATE IN THE OUTPUT OF THE AUTO PUMP ROUTE OUTPUT PRESSURE LINE DOWNWARD FROM AUTO PUMP TO PERMIT MOISTURE TO DRAIN AWAY CONDENSATE TRAP MUST BE DRAINED WEEKLY WATER IN THE PUMP OUTLET WILL INDUCE FAILURE WATER DAMAGE WILL VOID WARRANTY ...

Page 4: ...connections for air lines are 1 4 NPT Use Teflon tape or equivalent on all connections to insure no leakage of air 5 The recommended installation of the Auto Pump air compressor system is shown below 6 Note that an external check valve is located between the compressor and the pressure switch No additional check valve is required 7 Mount the air compressor Connect a suitable piece of flexible tubi...

Page 5: ...y be plugged into an available outlet or the cord may be cut and permanently wired to the 120 volt A C system in the vehicle SPECIFICATION Input 120 volts A C 60 Hz 4 amps Weight 13 lbs Motor Horsepower 1 8 HP Motor Type Split capacitor A C Pressure Switch set to 110 PSI Cut in 125 PSI Cut out Outlet Connection 1 4 NPT Female ...

Page 6: ... returned after repair shipping charges paid Kussmaul Electronics Company Inc shall have no liability for damages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The purchaser by the acceptance of the equipment assumes all liability for any damages which may result from its installation use or misuse by the purchaser his...

Reviews: