GENERAL INFORMATION
11
POWER / DATA CONNECTOR
The user configures the format of the serial data that
comes out the data port. There are several different
protocol formats and baud rates to choose from. The pin
out for the Power / Data connector is as follows:
1.
Brown – Input power (8 – 16 VDC)
2.
White – RS232 data into the DRU III
3.
Blue – RS232 data out of the DRU III
4.
Black -- Hold Control
5.
Gray -- Ground
6.
Pink – Open collector alarm
LED INDICATOR
The DRU III has a bicolor LED to indicate the status of
the current strongest valid target. The statuses the LED
can indicate are as follows:
1.
Short burst of flashing red = DRU III is running, no
valid target present.
2.
Red flashing at 50% duty cycle = strongest target is
not moving.
3.
Solid Red = strongest target is receding.
4.
Solid Green = strongest target is approaching.