background image

Port-A-Cool, LLC • 709 Southview Circle • Center, TX  75935 

www.kuulaire.com • 1-888-999-6511

2

Introduction

The PACKA44 and PACKA442205060 feature a 3-speed 

fan and automatic timer that can be programmed for 

0.5 hour to 7.5 hours. The automatic louver sweep 

function provides directional control and the remote 

control (batteries not included), provides convenience.  

The PACKA44 and PACKA442205060 portable evaporative 

cooler is the latest in evaporative cooling technology 

from Port-A-Cool, LLC, manufacturer of world-class 

portable cooling units, for residential, industrial and 

commercial applications. 

WARNINGS AND SAFETY RULES 

▲ 

LOCATION 

PARTS DESCRIPTION 

 

 

ELECTRICAL 

ASSEMBLY INSTRUCTIONS 

WARRANTY 

CLEANING AND MAINTENANCE 

TECHNICAL SPECIFICATIONS 

TROUBLESHOOTING 

REMOTE CONTROL 

USE AND OPERATION 

!

1.  This unit is intended for indoor use.  Any other use 

is not recommended and may cause fire, electric 

hazard, or injury to persons or property, and may 

void the warranty.

2.  Unplug the unit from power outlet when filling and 

refilling water reservoir.

3.  Unplug the unit from power outlet when moving 

the unit.

4.  Unplug the unit from power outlet when cleaning 

or servicing.

5.  Do not use the unit in areas where gasoline, paint 

or any other flammable chemicals are stored.

6.  Extreme caution should be taken when used near 

children and the elderly.  The unit should not be 

left unattended for any extended period of time 

while in operation.

7.  Do not let children play with any packaging 

material.

8.  Do not operate the unit with a damaged power 

cord.

9.  Do not attempt to repair or adjust any electrical or 

mechanical functions of the unit.

10.  The PACKA44 unit should run on 110-120V 60Hz AC 

only. The PACKA442205060 on 220-240V 50/60 Hz 

AC only .

11.  Do not cover unit air inlet or air outlet openings.

12.  This product is not intended for use in wet or damp 

locations.

13.  When not in use, drain the water from the tank and 

store the unit in a dry location.

14.  Do not run power cord under carpeting or cover 

with rugs or runners.  Arrange the cord away from 

areas where it may be tripped over.

15.  Do not use the unit with an extension cable.

16.  Do not insert or allow objects to enter the air 

outlet opening, as this may cause damage to the 

blower and may void the warranty.

17.  Use only fresh water to fill the water reservoir. 

The use of air fresheners or cleaners is not 

recommended as it may damage the unit and void 

the warranty.

18.  Drain the reservoir once every week to reduce 

calcium saturation.

19.  The unit is built with a water pump which has a 

feature to stop when water in reservoir is at low 

water.  The pump will restart when the reservoir is 

refilled with water. 

20.  Do not use this appliance with any solid-state 

speed control device.

21.  If the unit is damaged or malfunctioning, 

discontinue operation and refer to the trouble-

shooting section and/or contact a service 

technician

Basic safety precautions should always be followed when using any electrical appliance.

1.  Control Panel

2.  Horizontal Louvers

3.  Water Level Gauge

4.  Caster

5.  Water Fill

6.  Power Cord

7.  Water Reservoir

8.  Filter Cover

9.  Drain Plug

WARNINGS AND SAFETY RULES 

▲ 

LOCATION 

PARTS DESCRIPTION 

 

 

ELECTRICAL 

ASSEMBLY INSTRUCTIONS 

WARRANTY 

CLEANING AND MAINTENANCE 

TECHNICAL SPECIFICATIONS 

TROUBLESHOOTING 

REMOTE CONTROL 

USE AND OPERATION 

!

Summary of Contents for PACKA44

Page 1: ...HESE IMPORTANT INSTRUCTIONS Read all instructions carefully before setting up and operating this unit This manual was designed to provide you with important information needed to setup operate maintain and trouble shoot your cooler Failure to follow these instructions may damage and or impair its operation and void the warranty Owner s Manual ...

Page 2: ...with a damaged power cord 9 Do not attempt to repair or adjust any electrical or mechanical functions of the unit 10 The PACKA44 unit should run on 110 120V 60Hz AC only The PACKA442205060 on 220 240V 50 60 Hz AC only 11 Do not cover unit air inlet or air outlet openings 12 This product is not intended for use in wet or damp locations 13 When not in use drain the water from the tank and store the ...

Page 3: ...nsor alarm When water in the tank is below minimum level you will hear 15 beeps and COOL LED indicator will flash continuously At the same time the power to the pump will be cut off to protect the life of the pump In order to disengage the alarm function turn off and unplug the unit from the power outlet and fill the tank with water above the minimum level In order to turn off the alarm function a...

Page 4: ...water mineral build up and extend the life of the honey comb media pad A damp cloth can be used to remove calcium build up inside and outside of the unit When operating the unit turn Water Flow Control Knob to OFF position to dry out the pad The dust filter cover can be removed easily and can be cleaned weekly The inside of the water reservoir can be cleaned once or twice in a season to maintain a...

Page 5: ... turn off Remote Control Batteries Check batteries Calcium Build up in Blower Deep clean unit remove calcium debris Water Flow Control truned too low Change water flow control setting Unit is making noise Calcium Build up in Blower Deep clean unit remove calcium debris Water Flow Control truned too low Change water flow control setting Not cooling Low No Water Check water level Water Level Sensor ...

Page 6: ...ciones importantes Lea todas las instrucciones cuidadosamente antes de instalar y usar esta unidad Este manual esta diseñado para proveerle importante información necesaria para instalar usar mantener y solucionar problemas menores para su unidad La falta de seguir estas instrucciones puede dañar y o deteriorar el uso y anular la garantía MANUAL DE USUARIO ...

Page 7: ... con 110 120v 60 solamente y PACKA44 en 220 40v 50 AC solamente 11 No cubra las entradas o salidas de aire en el aparato 12 Este producto no esta hecho para locaciones mojadas o de extrema humedad 13 Cuando la unidad no esta en uso drene el agua y guárdelo en un área seca 14 No pase corriente bajo carpetas cubra con mantas o muebles con ruedas 15 No use una extensión con este aparato 16 No inserte...

Page 8: ...con un censor de alarma de agua Cuando el agua en el tanque esta en el nivel mínimo usted escuchara 15 sonidos y una luz se prendera y apagara continuamente A la misma vez la bomba se apagara para proteger la vida de la bomba Para silenciar la alarma apague la unidad y desconecte la unidad de la corriente de energía y rellene con agua arribe del nivel mínimo de agua Para apagar la alarma y seguir ...

Page 9: ...o tierra Nunca use detergentes disolventes o líquidos corrosivos para limpiar la unidad Cuando no se use drene el agua de la reserva y guarde la unidad en un área seca y fuera del sol MANTENIMIENTO Drenaje regular por lo menos una vez ala semana reducirá los almacenes de minerales y prolongara la vida de los paneles Un trapo mojado se puede usar para retirar calcio almacenado afuera y adentro de l...

Page 10: ...eserva Limpie la unidad profundamente retire los desecho de calcio Si el nivel de agua esta casi vacío la bomba creara un sonido No esta enfriando Nivel de agua bajo No Agua El censor del nivel de agua esta atorado Verifique el nivel de agua Drene rellene con agua fresca y o limpie el tanque de agua Omisión de olor Nueva unidad Vieja unidad con algas Cuando la unidad es usada por primera vez los m...

Reviews: