Description of Air Input System
3-11
KVAL Operation/Service Manual
Changing the Bit on 960-3 High Frequency Motor
This Service Note describes the process to change the Router Bit on 960-3 high frequency motor.
The process includes removing the motor to access the bit. Follow the steps below.
See “Appendix: Router Collet Assembly Basics” on page 3-16. This appendix
addresses Router Collect basics.
The 960-3 System is a powerful electro-mechanical motion con
-
trol system. Follow all safety and lockout tagout procedures.
Fail
-
ure to do so can result in damage to equipment and/or serious
injury to personnel.
Step 1
After locking and tagging out the machine,
remove the guard to allow space for motor
removal.
a.Remove the four wing nuts from the
front guard. Set them aside in a safe
place.
b.Carefully slide out the guard. Set aside.
Wing
Nuts
Summary of Contents for 960-3