System IT Administration
2-2
965X Service Manual
System IT Administration
For optimum support, the machines require internet access. With internet access, KVAL Service
Support will be able to access your machine through your company’s Intranet and help solve any
issues that may occur. Connection to the Intranet is achieved by interfacing with the machine’s
controller. The location of the Intranet connection is identified in
Figure 2- 1
(RJ45 to Intranet.)
About the 965X Line Computer
The
965X
Line uses a Beckhoff
®
CPU module as a PLC (Programmable Logic Controller.) In
addition to the CPU and the chipset, the module also contains internal main memory. The com
-
puter has a removable Compact Flash card from which it boots. Each controller utilize a Win
-
dows
®
based operating system with TwinCAT 2
®
automation software to create the PLC and
Motion Control method.
Interface modules include:
• A smart power supply to connect to EtherCat
®
terminals. This supply contains a
LCD to display system and user messages.
• A DVI/USB module to connect to the user interface.
• An Ethernet module to connect to the servo amplifiers.
Connections on the PLC
FIGURE 2- 1.
Connections on the Controller
Power Supply
PLC
To
Intranet
To Frame
Node
To Servo
Controllers