Operator’s Tour
2-15
KVAL 990-F4 Operation Manual
About the Hopper
The Hopper sorts the screws for delivery to the screw gun. The Hopper is attached to the Frame
Interface which in-turn is attached to the Six Shooter.The Frame Interface allow the six shooter
assembly to move across the machine.
Important:
Do not adjust any of the Hopper air cylinders. They are adjusted at the
factory. Any adjustment may cause timing issues with the operation of
the Six Shooter. If you think problems are being caused by the cylinders,
please contact the KVAL Service Department for direction.
FIGURE2- 8.
Hopper and Frame Interface
Important:
Do not put Magnetized Screws in Hopper. Magne
-
tized screws can cause sluggish response to screws
getting stuck. Hopper plates could get magnetized
and will have to be demagnetized with a degausser.
Hopper
Opt. Z Quick
Change Dump
Gate
Opt. Z Quick
Change Dump
Cylinder and
Funnel
Opt. Z Quick
Change Dump
Container
Frame Interface
Hopper Cylinder
Screw Pick
Off Slide
Assembly
Screw
Pick-Off
Cylinder
Screw Delivery Tubes
Air Injected
Six Shooter
Six Shooter Pivot
Cylinder
Track Wheels
Plate Assembly
Cylinder
Gate Assembly
Screw
Tracking
Plate
Assembly