Symptoms and Possible Causes
4-31
KVAL 990-F4 Service Manual
Six Shooter Lacks Power to
Drive Screws
1.
Bad Coupling
2.
Bad Parts in the Gear Box
3.
Faulty Pressure Relief Valve
4.
Bad Hydraulic Motor or Pump
1.
Replace Coupler
2.
Replace Parts or Rebuild
3.
Replace Valve
4.
Replace or Rebuild
Router Fails to Extend to
Pocket Position
1.
Six Shooter not Actuating the Limit
Switch for the Home Locations
2.
Limit Switch Out of Adjustment
1.
Move to Home Location
2.
Adjust Limit Switch Arm
Hinge Section Routers Cycle
but will not Rout out the
1.
Horizontal Router Ferrous Proxim
-
ity Sensor not Sensing
1.
Look For Obstructions
2.
Adjust Ferrous Proximity to within
1/31” or the reading surface
Router Fails to Operate
1.
Bad Fuse
2.
Routers Unplugged
3.
Bad Brushes
1.
Replace Fuses
2.
Plug In
3.
Replace Brushes
Routers Stuck in Pocket
Position (Pre-Drill Only
1.
Emergency Stop has Occurred
2.
Power Failure Thru Beams Out of
Alignment
1.
Re-energize Computer
2.
Hit Router Out of Pocket Position
3.
Re-align thru Beams
Six Shooter Not Dropping
Screws
1.
Air Valve Off
2.
Empty Hopper
3.
Jammed Split Shells
1.
Slide Air Valve On
2.
Put Screws in the Hopper
3.
Disassemble the Screw Receiver
Routers Not Moving Into
Home Position
1.
Through Beams Not Lined Up
1.
Pick Up on the Last Router Carriage
to realign.
TABLE 4-2.
Symptom
Possible Cause
Corrective Action