Replacing Bits
5-15
KVAL 990-HB Operation / Service Manual
2.
Disconnect air from Six-Shooter using the air-connect slide valves. Slowly slide the
valves back toward you; listen for air to be released.
3.
Pull the Six-Shooter assembly toward the machine-it will move slightly.
4.
Locate the back slide near the air valves (see images); push slide away from you.
This allows for movement of the Six-Shooter assembly away from the machine.
5.
Move the Six-Shooter assembly away from the machine-it will move about 1½ inch.
This provides room for hands to access the screwdriver bit holders.
6.
To remove screwdriver bit, push the bit holder (see images) back toward the Six-
Shooter assembly and hold: pull bit out of holder.
Slide Back
Bit Holder
7.
To insert screwdriver bit, push bit holder back toward Six-Shooter assembly and
hold while inserting new bit. Release holder to secure bit.
8.
Move Six-Shooter assembly back toward machine and pull the back slide toward
you; then move assembly away from machine to restore assembly to original start-
ing position