Powering Operations for the 990-HB
2-19
KVAL 990-HB Operation / Service Manual
Powering Operations for the 990-HB
This section describes how to power up and to power down the 990-HB.
Powering up the system includes:
• Applying power to the entire system
• Starting the Control Circuit
Powering down the system includes:
• Shutting down the control power
• Removing power from the entire system
How to Power Up the 990-HB
1.
Ensure factory air is applied to machine and main air supply is turned on.
2.
Check to make sure all E-Stop buttons are out.
Note:
A pop-up is displayed on the user screen if an E-Stop is pressed. The pop-up will
indicate which E-Stop has been activated
3.
Make sure the electrical disconnect the electrical cabinet is turned to the ON posi-
tion.
4.
Pull out the
CONTROL TRANS-
FORMER
switch. It should light
up.
5.
Push the green
START MACHINE
button.
6.
All lights on the status light panel on the electrical
box should be illuminated. See “Description of the
Six Light Panel” on page 2-14
Note:
If a status light does not turn on during the power
up process, see “Troubleshooting with the Status
Light Panel” on page 6-7 for assistance in identi-
fying the issue.
.
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...