Width Adjust Operation
Width Adjust:
•
Open
:
Press and
hold
the
Open
button to
open the width adjust carriage. To stop the
carriage, release the button. The carriage
will also stop if the positive travel limit eye
is activated.
•
Close:
Press and
hold
the
Close
button to
close the width adjust carriage. To stop the
carriage, release the button. The carriage
will also stop if the negative travel limit eye
is activated.
Door:
•
Stop:
Press the
Stop
button to extend or retract the appropriate door stop.
•
Clamp
:
Press
Clamp
to activate the cylinders that clamp the door.
Feed:
•
Reverse:
Press and hold the
Reverse
button reverse the feed of the door. To stop
the feed, release the button.
•
Forward:
Press and hold the
Forward
button to move the door feed forward. To stop
the feed, release the button.
•
Normal Speed:
Press and hold the
Normal Speed
button to slow speed. To return to
previous speed, release the button.
Toggle Buttons:
The buttons to the right toggle auto functions on or off. For descriptions of these but-
tons, see “Auto Enable and Disable Buttons” on page 2-27 .
Additional Functions Operation
Skip Hinge 1-3:
Select to Skip the hinge route and
drill functions any hinge.
Test Mode:
Select to toggle the Test Mode on or
off.
Test Mode runs the hinge cycle, but does not
extend the tools. This is primarily used to verify a new template is correct and the
hinge carriage will not bump into the H-Block or other assemblies.
About Manual Operation
2-36
KVAL 990-HB Operation / Service Manual
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...