Check Specifications of the Front Section
3-8
KVAL 990-HB Operation / Service Manual
Step 1: Hinge Carriage Calibration
Adjusting the X Axis
1.
Run the Calibration Routine. See “Run the Calibration Routine” on page 3-6. Use
the H Block as a reference to determine the horizontal center of the calibration slot.
Figure 3- 6 on page 3-9, shows an example of left and right
off center
locations.
2.
Measure the amount of material left between the H-block and the slot on both sides
of the slot (a and b).
3.
Calculate the difference between “a “and “b” and then divide by two. See Figure 3-
4.
Next, what way does the slot need to move? To move to the left, enter a positive
number. To move to the right enter a negative number.
5.
Locate the appropriate Menu in the
Setup interface screens
6.
If there is a number in the box under X-Axis, select the
Combine with Base
button to
set a reference.
7.
Once this number is added to the base, double select the box that has 0.000. A calcu-
lator will be displayed. Enter the offset in this box.
8.
If it needs to go in the negative direction, select the negative symbol.
9.
Select the check mark to confirm this number and exit to go back to the Setup
screen.
10.
Exit out of the Setup screen and rerun the Calibration test.
11.
Re-measure the slot.
12.
If slot is not centered, repeat the steps above until the slot is centered.
13.
After centering is achieved, select
Combine with Base
to store the corrections.
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...