Check Specifications of the Front Section
3-12
KVAL 990-HB Operation / Service Manual
Summary of Calibration Steps:
1.
Run the Calibration Slot cut.
2.
Check, measure, and calculate specifications of Counter Rotate Router cut.
3.
To set a new reference, go to the calibration menu and click “Combine with Base”
4.
Enter calculations.
X:
If the Counter Rotate Router cut position is to the
right-enter negative number. If cut position is to the left -
enter a positive number
Y:
If the Counter Rotate Router cut position is high-
enter negative number. If cut position is low-enter a
positive number
Z:
If the Counter Rotate Router Cut depth is too deep
enter a negative number. If cut is shallow -enter a posi-
tive number
Diameter:
The diameter menu allows adjustment com-
pensate for discrepancies to the actual size of the
router bit.
5.
Repeat until cut is centered.
6.
Click “Combine with Base” to finish.
-
Step 4: Pre-Drill Calibration
Verify the Pre-Drill
• The depth of the pre-drill should be 19.00 mm deep.
• The
hole should be centered in the H-block and center on the thickness of the door
Adjusting the Pre-Drill
1.
Run the Calibration Routine. See “Run the Calibration Routine” on page 3-6.
2.
Check, measure, and calculate specifications of Pre-Drill cut.
3.
To set a new reference, go to the calibration menu and select
Combine with Base
.
4.
Enter calculations.
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...