X:
If Pre Drill hole position is to the right-enter positive num-
ber. If hole position is to the left -enter a negative number
Y:
If Pre-Drill Hole position is high-enter negative number. If
hole position is too low-enter a positive number
Z:
If the Pre-Drill hole is too deep enter a negative number.
If hole is too shallow enough -enter a positive number
Check Specifications of the Front Section
3-13
KVAL 990-HB Operation / Service Manual
FIGURE 3- 9.
Pre-Drill Router Calibration Menu
5.
Repeat until hole is centered.
6.
Select
Combine with Base
to finish.
Step 5: Chisel Calibration
Once the routers are calibrated, the chisels need to be checked. In order to verify the chisels, a
door and a jamb will be required for this procedure.
1.
Load in a known hinge pattern and make sure the chisels are turned on. Run one
hinge for this calibration.
2.
Check that the H-block is setup in the correct location.
3.
Run the hinge.
4.
After the hinge run is finished, check all four corners of the hinge to see if the chis-
els are in the correct location.
5.
If the corners of the hinge are out of specification, continue the process on the next
page.
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...