Calibration of the Back Section
3-16
KVAL 990-HB Operation / Service Manual
Lock Location Calibration
To start, run a known good lock cut at a standard location on
a Right Hand or Left Hand door.
Once the lock cut is completed, check the distance from the
top of the door to the center of the lock.
Note the measurement value and compare to specification
If the lock location is correct, there is no need to perform
this process, If it is not correct, follow the instructions in See “Adjusting
Lock Location” below.
Measure
FIGURE 3- 11.
Reference Door Lock
Adjusting Lock Location
1.
Select the size door (
6'8''-7'0''-8'0'') or Base.
2.
Select Right Hand or Left Hand depending on the door
run through process.
3.
Under Base, select the
Combine with Base
button.
4.
Enter a positive number to move the lock towards the bot-
tom of the door (left) or a negative number to move the
lock towards the top of the door (right).
5.
Re-run the lock cut.
6.
Measure again and repeat steps 3 to 4 until the center of
the lock is at the desired cut location.
7.
Once the completed with calibration, select the
Combine
with Base
button to store the data.
8.
Exit Main Calibration Screen.
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...