Calibration of the Back Section
3-17
KVAL 990-HB Operation / Service Manual
Lock Bore Calibration
Run a known good lock bore at a standard location on a Right Hand or Left Hand door.
Once the lock bore is completed, check the distance from the top of the door to the center of the
bore hole. Note the measurement value.
Measure
Adjusting Strike Plate Location
1.
Use the difference from the expected result
from the actual results and enter them into
the boxes in Lock Bore Location.
2.
Under Base, select the
Combine with Base
button.
3.
Enter a positive number to move the lock
bore towards the bottom of the door (left) or
a negative number to move it towards the
top of the door (right).
4.
Re-run the door.
5.
Measure again and repeat steps 3 to 4 until
the center of the lock bore is at the desired
cut location.
6.
Once the completed with calibration, select the
Combine with Base
button to
store the data.
7.
Exit Main Calibration Screen.