System IT Administration
4-2
KVAL 990-HB Operation / Service Manual
System IT Administration
For optimum support, the 990-HB requires internet access. With internet access, KVAL Service
Support will be able to access your machine through your company’s Intranet and help solve any
issues that may occur. Connection to the Intranet is achieved by interfacing with the 990-HB con-
troller. The location of the Intranet connection is identified in the figure below (RJ45 to Intranet.)
About the 990-HB Computer
The 990-HB uses a Beckhoff
®
CPU module as a PLC (Programmable Logic Controller.) In addi-
tion to the CPU and the chipset, the module also contains internal main memory. The computer
has a removable Compact Flash card from which it boots.The controller uses a Windows 7
®
oper-
ating system with TwinCAT 2
®
automation software to create the PLC and Motion Control
method.
Interface modules include:
• A smart power supply to connect to EtherCat
®
terminals. This supply contains a
LCD to display system and user messages.
• A DVI/USB module to connect to the user interface.
• An Ethernet module to connect to the servo amplifiers.
Connections on the PLC
The CPU module is located in the upper left corner of the Electrical Panel. See “About the Electri-
cal Panels” on page 2-13.
Smart Power Supply
and EtherCat
DVI/USB Module
to User Interface
CPU Module
RJ45 to
Intranet
Compact
Flash Card
Interface to
Servos
Battery
Interface to
Frame
FIGURE4- 12.
Connections on the Controller
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...