Replacing Bits
5-12
KVAL 990-HB Operation / Service Manual
How to Access to Bit Assemblies
1.
Shutdown the machine and follow the “Lock Out Tag Out procedures.
2.
After machine is locked and tagged out, loosen remove the screws from the Top
Dust Cover.
3.
Fold back cover to access the bit assemblies.
Remove and Replace the Router or Pre-Drill Bits
After lockout tagout and access has been obtained to the assemblies, follow these
instructions to remove and replace the router bit or the pre-drill bit.
1.
Use a 17 mm shaft wrench and a 3/8 “collet wrench to remove the bit on the pre-drill
or router assemblies.See
3/ 8 “Collet Wrench
17 mm Shaft Wrench
FIGURE5- 21.
Removing Pre-Drill or Router Bit.
2.
Inspect and clean collet assembly.
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...