Mechanical set up of the 990-HB
5-16
KVAL 990-HB Operation / Service Manual
Mechanical set up of the 990-HB
Note:
Mechanical set up was made at the factory and little if any adjustments should
be made at initial setup.
This section describes the method to mechanically set the references for the front section and back
section of the 990-HB. Adjustment descriptions include:
Front Section
• Centering the Routers
• Pocket Center in H-Block
• H-Block Positioning
• Pre-Drill Positioning
• Door Stop Positioning
• Jamb Stop Positioning
Back Section
• Lock Positioning
• Bore and Faceplate Positioning
Front Section
Preliminary Hinge Center Set-Up
During preliminary hinge center set-up, the H-blocks must be positioned, door stops
must be set for the left and right hand doors, and jamb stops must be adjusted. During
this set-up procedure, check positioning of each of the assemblies before adjusting. In
most cases, they will already be positioned to your specifications by our technicians
during manufacturing.
Positioning H-Blocks
The first station is precision-located, and is the reference point for all set-up proce-
dures. A door does not need to be in the machine for initial setup. The goal of the set-
up is to distance between H-blocks to agree with you hinge center specifications.
1.
Measure center-line to center-line from the center routing station H-block to one of
the H-blocks on the outboard routing stations.
2.
If spacing is incorrect adjust the hinge center on the opposite end of the machine,
measuring from the center H-block. If adjustment is needed, loosen the two H-block
mounting bolts and nudge the block until the distance is the same as your specifica-
tions.
3.
Re-tighten routing station mounting bolts re-check measurement, adjust if neces-
sary.
4.
Repeat step 1-3 until hinge centers are to you specifications.
Summary of Contents for 990-HB
Page 4: ...KVAL 990 HB Operation Manual ...
Page 25: ...Safety Sign Off Sheet 1 17 KVAL 990 HB Operation Service Manual ...
Page 26: ...Safety Sign Off Sheet 1 18 KVAL 990 HB Operation Service Manual ...
Page 66: ...Diagnostic Screen 2 40 KVAL 990 HB Operation Service Manual ...
Page 84: ...Calibration of the Back Section 3 18 KVAL 990 HB Operation Service Manual ...
Page 88: ...System IT Administration 4 4 KVAL 990 HB Operation Service Manual ...