Safety First!
1-10
KVAL 990-HB Operation / Service Manual
Important:
When many people are all working on the same machine you will need a
multiple lockout device, such as the one shown here.
Follow the P-R-O-P-E-R lockout rule of thumb.
P......
Process shutdown
R ......
Recognize energy type (electrical, pneumatic, mechanical, etc.)
O......
OFF! Shut off all power sources and isolating devices
P......
Place lock and tag
E......
ENERGY: Release stored energy to a zero-energy state
R ......
Recheck controls and test to ensure they are in the “OFF” state