Run the Calibration Routine
3-6
KVAL 990-HB Operation / Service Manual
Run the Calibration Routine
After checking for common errors, start the calibration cut process.
Select Calibration
From the Main Screen, choose
Calibration
.
Select
Calibration
from the Menu list on
the Hinge Spec Group
NOTE
: If Calibration is not on the list,
contact KVAL service. KVAL service can
remotely download the program if LAN
and WEB enabled.
FIGURE 3- 3.
Select Door Parameters
From the Door section of the User Interface, choose the following below. See “Main Screen” on
page 2-24.
1.
Choose Door Height (Thickness)?
2.
Choose door Length.
3.
Disable three of the hinges leaving one hinge enabled.
Load the Door and Start the Cut
1.
Load the test door into the in-feed of the 990-HB.
2.
Verify the setup and check for machine is safe to run.
3.
Press the
Start
button, to begin the process.