About Manual Operation
KVAL 990-FX Operation Manual
2-20
Screw Delivery Manual Control
(Option) Quick Dump Hopper:
Press but
-
ton to dump the screws in an active
Hoppers.
Clear:
Press to clear screws in Hopper system.
Load:
Press this button to start the loading process of
the Hoppers
Air Injection:
Press to inject air into the Hopper sys
-
tem. Drive screws through tubes.
Shift Drivers In /Out:
The ''In'' button shifts the six
shooters over hinges. The ''Out'' button shifts the six shooter out of position.
Test Mode and Hinge Burn Chipout
Command Code:
Displays current command code.
Activate Command:
Press to activate the command
code in the box.
Test Mode:
Select to toggle the Test Mode on or
off.
Test Mode runs the hinge cycle, but does not extend the tools. This is primarily used
to verify a new template is correct and the hinge carriage will not bump into the H-