About the Setup Screen
KVAL 990-FX Operation Manual
2-24
Adjusting Lock Location
1.
Select the size door (
6'8''-7'0''-8'0'')
2.
Select Right Hand or Left Hand depending on the door run
through process.
3.
Under Base, select the
Combine with Base
button.
4.
Enter a positive number to move the lock cut to the left.
Enter a negative number to move the lock cut to the right.
5.
Re-run the lock cut.
6.
Measure again and repeat steps 3 to 4 until the center of the
lock is at the desired cut location.
7.
Once the completed with calibration, select the
Combine
with Base
button to store the data.
8.
Exit Main Calibration Screen.
Timing: Front Section and Back Section
Use the
Timing Controls
to tune the synchronization of
the
Carriage Head
routine and the
Face Plate
routine. If
Either process is finishing too soon or later than each
other, use the this routine.
Note:
This is rarely used. In some cases severe climate changes