Determine What:
What Subsystem is
Responsible for the Failed
Sequence Step.
Analyze
the subsystem:
Check the Load.
Check the
Position Feed Back
.
Check the
Positioning System
See
TABLE 6- 1.
Typical KVAL Machine Sequence
Typical Machine Sequence
Responsible Subsystem
1. Move Door into Position
Feed System
2. Clamp the Door
Door Clamp
3. Make the Cuts
Cutter Positioning
Cutter Power
4. Unclamp the Door
Door Clamp
5. Move Door Out
Feed System
6. Wait for Next Door
Feed System
Basic Troubleshooting Steps
Determine Where:
The Sequence Step
Where
the Failure Occurs
What was the Machine Trying to Do?
What Was the Machine Trying to Do
Next?
How is the Broken Section Suppose to
What is Keeping the Broken Section From
Working?
What Part of the Machine is not Work-
ing?
Ask
Narrow
Verify
Troubleshooting Basics
KVAL 994-X Operation/Service Manual
6-8
Analyze the Sub Systems
1.
Check the
Load
for mechanical issues
• Is the Load “bound up?
• Is there sufficient lubrication?
• Is it an alignment issue?
• Is anything damaged?
2.
Check the
Position Feed Back
.
• Does the
Position Feed Back
agree with the
Load
position?
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Service Manual ...
Page 31: ...Safety Sign Off Sheet 1 21 KVAL 994 X Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet KVAL 994 X Operation Service Manual 1 22 ...
Page 110: ...Calibration of the Back Section KVAL 994 X Operation Service Manual 3 22 ...
Page 114: ...System IT Administration KVAL 994 X Operation Service Manual 4 4 ...
Page 144: ...Collet Torque Values KVAL 994 X Operation Service Manual 5 30 ...
Page 180: ...Symptoms and Possible Causes KVAL 994 X Operation Service Manual 6 36 ...
Page 185: ......
Page 186: ......
Page 187: ......